Replace Batteries

When the batteries of an Analog Clock need to be replaced, its second hand advances and pauses continuously (stepping) until
the batteries are replaced. The clock may display the correct time, but the batteries should be replaced promptly to restore normal
operation. The stepping pattern continues until its batteries are replaced.
Battery use requirements
New, high quality alkaline batteries.
l
Batteries should be the same type and date code.
l
The battery expiration date should be at least 5 years in the future.
l
The use of heavy duty and zinc carbon batteries is NOT recommended as they have a shorter life span and have risk of leakage
l
if over discharged.
Do NOT use rechargeable NiCad batteries as their output voltage is too low to assure proper operation.
l
Do NOT use standard lithium batteries.
l
How to replace batteries for an Automatic Setting Analog Clock
1. Remove the clock from its location to access the back of the clock.
2. Remove its batteries and wait 10 seconds.
3. Stretch the battery tabs in the battery holder out slightly to apply more pressure to the battery contacts.
4. Insert two new alkaline batteries. It's important to insert the batteries with the battery '+' end to '+' end of the battery holder
to achieve proper battery orientation.
When both batteries are in place, the clock automatically initiates the Self Initialization procedure to set its time.
12