Page 1
Levo Digital Clock and Timer Install Guide OneVue Sync PoE Product Models: C2005, X202F Publication date May 4, 2020...
Page 2
OneVue is a trademark of Primex. All other trademarks are the property of their respective owners. Primex is the leading provider of solutions to automate and maintain facility compliance, increase efficiencies, enhance safety and reduce risk for enterprise organizations in the healthcare, education, manufacturing and government vertical markets. Primex delivers solutions that utilize a facility’s existing network infrastructure to automate, monitor, document and report essential activities...
Code Blue Timer operation overview ..................25 IMPORTANT SAFETY INSTRUCTIONS ....................27 REGULATORY APPROVALS ......................28 ONE YEAR LIMITED WARRANTY ...................... 29 Technical Support ......................... 30 Support through Primex Certified Sales and Service Partners ............30 Primex Technical Support ...................... 30 Page 3...
PoE Levo Series Digital Clock/Timer Specifications Device specifications Power over Ethernet PoE.IEEE 802.3af Compliant (PoE) Maximum power consumption: 12.9 Watts (Class 3) AC power supply 120 VAC (100-240)/ 50–60 cycle, 10 ft. (3.0 m) cord with two-prong plug, UL/cUL listed (optional accessory) Enclosure Enclosure: ABS plastic...
Page 5
A. Key-Hole Mount (2) B. AC power supply and power cord with 2-prong plug (AC model). Power cord strain relief assembly with supplied washer and screw. C. RJ45 port (PoE model) D. RJ11 port (elapsed timer and code blue timer model): connection to supplied Timer Switch Control E.
• Ethernet cable: CAT 5 or higher. • AC power/wired Ethernet network use: A Primex AC power adapter can be used to supply power to allow connection to a wired Ethernet network or when power is not supplied by an RJ45 enabled port or PoE switch.
Install Digital Clock/Timer: Wall mount with tilt bracket A Digital Clock/Timer can be wall mounted at a 4° or 18° angle with use of the supplied tilt bracket. Tilt bracket mounting dimensions • Dimension D: Clock screw hole spacing. • Dimension E: Distance to wall surface for 4° mounting bracket •...
Assemble and mount to tilt bracket NOTE Hardwired (pigtail) install: AC-powered clocks are supplied with a power cord with a two-prong plug. The two-prong plug may be removed for a hardwired (pigtail) installation. Hardwired installation requires a 120V~ power line in a junction box installed by a licensed electrician. Leave a minimum of 6 in.
Remove digital clock/timer from tilt bracket • 2.5" model: From the top of the bracket using a screwdriver press each hook down to release the clock and pull out to unsnap bottom hinges. • 4” model: From the top of the bracket, insert a thin screwdriver into each notch and gently move the screwdriver sideways to unlock the clock, pull clock forward and up to unsnap, and lift out.
Install Digital Clock/Timer: Wall mount with keyhole A Digital Clock/Timer can be mounted directly to the surface of a wall by use of the clock keyhole mounts and the supplied screws and anchors. Mounting dimensions • Dimension D: Clock screw hole spacing. •...
Directly mount a clock/timer to the surface of a wall Most building codes prohibit the use of hardwired power connections for devices that can be removed without tools. A clock/timer mounted directly to a wall is required to have a standard power plug. •...
Install Digital Clock/timer: Dual-sided bracket kit A dual-sided Digital Clock/Timer consists of two single-sided clocks/timers and a dual bracket kit. The kit includes a dual housing bracket, a flange that mounts to ceiling or wall, and the hardware necessary to complete the installation. Using the kit, you combine the two single-sided clocks to create a dual-sided clock.
Assemble and mount a dual-sided digital clock/timer On the wall or ceiling, measure and drill holes with the correct spacing to mount the flange over the junction box. Attach the flange to the wall or ceiling using the toggle anchors and the longer machine screws provided. Wall-mount: if the mounting location is outside of the junction box, break off or cut openings in the flange to route power cords.
Remove from dual mount bracket 2.5” model: From the top of the bracket, using a screwdriver press each hook down to release the clock. Then pull out to unsnap bottom hinges. 4” model: From the top of the bracket, insert a thin screwdriver into each notch and gently move the screwdriver sideways to unlock the clock, pull clock forward and up to unsnap, and lift out.
Install Digital Clock/Timer: Flush mount A flush mount model can be installed onto a new or existing wall surface. Supplied components Quantity Component Flush mount junction box (Material: ABS plastic, color black, and UL Rated 94-V0) Bezel (material: ABS plastic, color black, and UL Rated 94-V0) #10 Phillips Flat Head Screw Drywall Anchor Dimension specifications...
Install flush mount clock/timer Mount the junction box. • New wall surface Mount junction box to wall studs using four common drywall screws (not supplied), as shown in Figure 1, “New wall surface assembly illustration” [18]. Remove the applicable conduit knockout(s) for the incoming AC power (PoE optional: for AC backup power use only), and the timer input for a timer model only.
Install Timer Control Switch Elapsed Timers and Code Blue Timers include a three-button Timer Control Switch that controls end-user timer events. • InfoBoards can operate as an Elapsed Timer with both count up and count down options. The three-button Timer Control Switch allows a user to start, pause, stop, and reset the count events, and set an event to begin at a specific time increment.
Step 3: Mount Timer Control Switch to junction box Timer Control Switch is required to be mounted to a single-gang junction box (not supplied). The junction box dimension is typically 2.25 in. x 2.75 in. x 4 in. (5.72 cm x 6.99 cm x 10.16 cm). Page 20...
Operate Elapsed Timer An Elapsed Timer is a multi-function device that can operate as a digital clock displaying its synchronized time and as a timer with both count up and count down options. The three-button Timer Control Switch allows a user to start, stop, pause and reset the timer, and set its start time.
Clock Mode Count Up Mode Count Down Mode 10:45 02 0.0:00 00 99:59 59. Displays current time Decimal lit after the 10 hr digit Decimal lit after the 1 sec digit When power is first applied Count Up event can count from Count Down event can count down and when not in a count 00:00:00 up to a maximum of 99:59:59...
To automatically stop the current count event and reset the count to its start time, press and release the RESET button once. To return to Clock Mode, which displays its synchronized time, press and release the DISPLAY button until the current time is displayed.
Page 24
Set to Count Down mode, press and release the DISPLAY button until 99:59 59 or its previously set start time is displayed, indicating it is in Count Down mode. Press and hold the SET/CHANGE button for 3 seconds to enter Set state, which is initially indicated by “ _ _:_ _ _ _” on the display and then the timer displays the last start time set or the default start time of 99:59 59.
Operate a Code Blue Timer A Code Blue Timer is a multi-function device that can operate as a digital clock displaying synchronized time and a timer that integrates with an existing code blue system that triggers its code blue events. Code Blue Timer operation overview •...
Page 26
Pressing the button... Active Code Blue Event Mode Halted Mode DISPLAY (EXIT) Ignored Exits code blue mode and sets timer back to Holding down DISPLAY (EXIT) for a minimum of clock mode. four seconds will display the time of the last code blue event.
IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLATION, OPERATION, OR MAINTENANCE OF PRODUCT. Some of the following information may not apply to your particular product model; however, as with any electronic product, precautions should be observed during installation, operation, and maintenance. •...
REGULATORY APPROVALS FCC Compliance FCC Compliance Pursuant to FCC 15.21 of the FCC rules, changes not expressly approved by Primex might cause harmful interference and void the FCC authorization to operate this product. FCC Radio Frequency Interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Primex, Inc. warrants this product to be free from defects in materials and workmanship for a standard of one (1) year from the date of purchase. Primex, Inc. will at its sole option, repair or replace any components that fail in normal use.
Ensuring our customers experience excellent service is of utmost importance to Primex. Our network of Certified Sales and Service Partners offers technical support services for Primex products. If you have purchased Primex products or have a service agreement with a Primex Partner, they are your primary contact for all Technical Support inquires.
Need help?
Do you have a question about the OneVue Sync Levo Series and is the answer not in the manual?
Questions and answers