Festo CPX DE Series Manual page 58

Cpx-i/o modules for cpx terminal
Hide thumbs Also See for CPX DE Series:
Table of Contents

Advertisement

2. MPA pneumatic modules
4
1
MPA1 pneumatic module
2
MPA2 pneumatic module
3
Addresses of coil 14 (channel 0, 2, 4, 6)
4
Addresses of coil 12 (channel 1, 3, 5, 7)
Fig. 2/5: Example: Address assignment of MPA pneumatic modules (viewed from above)
2−14
Address assignment within the pneumatic modules
An MPA1 pneumatic module always occupies 8 output
addresses, an MPA2 pneumatic modul always occupies
4 output addresses.
Each valve location occupies 2 addresses, irrespective of
whether a valve plate or blanking plate is fitted.
The following assignment applies:
solenoid coil 14 occupies the lower−value address,
solenoid coil 12 occupies the higher−value address.
1
12 14 12 14
12
14
3
5
2
14
12
14
12
7
6
5
5
Valve plates with two solenoid coils
6
Valve plates with one solenoid coil
(addresses Ox+5 unused)
7
Blanking plate
Festo P.BE−CPX−EA−E N en 05602d
14
3
4
3
4