Festo CPX DE Series Manual page 180

Cpx-i/o modules for cpx terminal
Hide thumbs Also See for CPX DE Series:
Table of Contents

Advertisement

A. Technical appendix
Technical specifications
General technical specifications of the CPX terminal
Protection class as per EN 60529
Operating voltage supply for electronics/sensors
(V
)
EL/SEN
Rated voltage
Internal current consumption at 24 V (internal
electronics)
Load voltage supply for valves (V
Rated voltage
Internal current consumption at 24 V (internal
electronics, without valves)
Diagnostic message undervoltage V
ing V
, load voltage outside function range)
VAL
Digital outputs (valve solenoid coils)
Rated load voltage
Intended for connecting to pneumatics
Short circuit protection at valve output
Monitoring wire fracture (open load)
Isolation
Electrical isolation
Between the channels (valve solenoid coils)
Between the operating voltage supply for the
electronics/sensors (V
voltage for the valves (V
Module code [Type code] (CPX−specific)
Module identification (Handheld)
A−4
)
VAL
(monitor
VAL
) and the load
EL/SEN
)
VAL
VABA−10S6−X1 for VTSA pneumatics
(ISO)
See CPX system manual
IP65, in fitted state
24 V DC ±25 %
Typ. 15 mA
24 V DC ±10 %
Typ. 30 mA
21.6 ... 21.5 V
Max. 32 outputs
V
VAL
VTSA (ISO, type 44)
Yes (electronic), response threshold> 1.0 A
Can be parametrized
Tested with 500 V DC
None
With power supply via manifold sub−base
type:
CPX−GE−EV−S: none
CPX−GE−EV−S−7/8−5POL: yes
CPX−GE−EV−V...: yes
69
ISO PlugIn or type 44
(depending on the version of the Handheld)
Festo P.BE−CPX−EA−E N en 05602d