Festo CPX DE Series Manual page 36

Cpx-i/o modules for cpx terminal
Hide thumbs Also See for CPX DE Series:
Table of Contents

Advertisement

1. Pneumatic interfaces
Module parameters: Monitoring the CPX module
Function no.
4828 + m * 64 + 0
Description
Monitoring of the possible faults can be activated or deactivated (suppressed)
for each module separately. Active monitoring causes the following: The fault is:
Monitoring
Bit
Description
2
Undervoltage of valves (V
3
Short circuit at the valve (SCV)
Values
1 = active
0 = inactive
Presetting: bit 2: active;
Remark
Monitoring can also be set for the complete CPX terminal
(see CPX system manual).
[...] = display in the Handheld
Tab. 1/4:
Monitoring the CPX module
1−16
Parameters of pneumatic interfaces types
CPX−GP−03−4.0, CPX−GP−CPA−... and VABA−10S6−X1
sent to the CPX field bus node
displayed by the common module fault LED.
bit 3: inactive
m = module number (0...47)
)
VAL
[Monitor]
[Monitor Vval]
[Monitor SCV]
[Active]
[Inactive]
Festo P.BE−CPX−EA−E N en 05602d

Hide quick links:

Advertisement

Table of Contents
loading