1. Pneumatic interfaces
1−10
Caution
Modules may be damaged if they are not handled
correctly.
Do not touch the electrical contacts of the modules.
·
Observe the regulations for handling electrostatically
·
sensitive components.
Discharge yourself electrostatically before fitting or re
·
moving components in order to protect the components
against discharges of static electricity.
Please note
Handle all modules and components of the CPX terminal
with great care. Please note especially the following:
Screws must be fitted accurately (otherwise threads will
·
be damaged).
Screws must be fastened at first only by hand. Place the
screws so that the self−cutting threads are used.
The specified torques must be observed.
·
Screw connections must be fitted free of offset and
·
mechanical tension.
Check the seals for damage (IP65).
·
Connecting surfaces must be clean (to ensure sealing
·
effect, avoid leakage and contact faults).
The screw connection between the cover and the lower
part of the CPA pneumatic interface is designed for at least
10 fitting/removal cycles.
Removing the cover
1. Loosen the screws in the cover with a TORX screwdriver
size T10.
2. Lift the cover up carefully.