A. Technical appendix
Technical specifications
General technical specifications of the CPX terminal See CPX system manual
Protection class as per EN 60529
Operating voltage supply for electronics/sensors
(V
)
EL/SEN
Rated voltage
Maximum internal current consumption at 24 V
(irrespective of switching status of the valves)
Load voltage supply for valves (V
Rated voltage
Maximum internal current consumption at 24 V
(irrespective of switching status of the valves)
Diagnostic message undervoltage V
ing V
, load voltage outside function range)
VAL
Digital outputs (valve solenoid coils)
Short circuit protection at valve output
Maximum current consumption per solenoid coil
out of load voltage V
Rated pick−up current/duration
Nominal current with current reduction
Isolation
Electrical isolation
Between the channels (valve solenoid coils)
Between the operating voltage supply for the
electronics/sensors (V
voltage for the valves (V
Module code [Type code] (CPX−specific)
Module identification (Handheld)
A−6
)
VAL
(monitor
VAL
at 24 V
VAL
) and the load
EL/SEN
)
VAL
VMPA2−FB−EMG−4
IP65, in fitted state (MPA pneumatic module
fitted completely)
24 V DC ±25 %
20 mA
24 V DC ±25 %
Typ. 25 mA
17.5...16.0 V
4 outputs
Yes (electronic)
90 mA / 20 ms
18 mA after 20 ms
Tested with 500 V DC
None
With power supply via manifold sub−base type:
CPX−GE−EV−S: none
...−EV−S−7/8−5POL:
yes
CPX−GE−EV−V...:
yes
81
MPA2G
Festo P.BE−CPX−EA−E N en 05602d
VMPA2−FB−EMS−4
24 V DC ±25 %
Typ. 8 mA
17.5...16.0 V
CPX−GE−EV−S: none
...−EV−S−7/8−5POL:
not permitted
CPX−GE−EV−V...:
not permitted
83
MPA2S