Parallel Outputs 0‐7 
Outputs are open collector to ground and can sink up to 125 mA of current each (actually, any 
output can sink up to 400 mA, however the maximum combined current should be kept below 
1000 mA). 
w
IMPORTANT!
Outputs on Zephyr Xstream motherboards prior to Rev G (1401-0000--007) cannot be used
with external pull ups higher than 5 volts.
If this ability is required, please contact Telos customer support.
These will include a 10k‐ohm 5 volt pull‐up resistor to allow direct interface with 5 volt logic 
inputs on other equipment.  If your other equipment uses a voltage greater than 5 volts, you will 
need and external pull up resistor, unless it is built‐in to that equipment's inputs.  An 
appropriate value is in the range if 2.2K
voltage less than 5 volts is not possible. 
If used with a relay or LED, then tie your external power source ground to pin 25 (or use the 5 
VDC power supplied on pin 1) and run this power source through your device, with a resistor in 
series to limit maximum current to less than 125 mA. 
The outputs can also be used for monitoring the status of the unit.  This functionality can be set 
by several menu selections in SYSTEM menu. Refer to Section 11.5 (Detailed Menu Reference) 
for the menu selections relating to these outputs. 
An external pull up resistor can be used if voltages greater than 5 volts are used. Alternatively, a
voltage source (such as the 5 volts on pin 1) can be driven through an external device (such as a
USER'S MANUAL
Ω
Ω
 to 10K
.  Operation with logic inputs requiring a 
Equivalent schematic for the Parallel Outputs.
relay or LED) into the input.
Section 3: GUIDED TOUR of the HARDWARE 52
+5 VDC
OUTPUT
(400 mA max)