5.6 Printer Adjustment/Maintenance (05)
• New adjustment value appears in the
"Calculated" box.
6. Select "All IDs" or "Selected ID only".
7. Enter ID in the "ID" box if "Selected ID only" is
selected.
8. Enter new adjustment value in the "New" box.
9. Click the [Set] button.
10. Click the [Close] button.
• Operation returns to the menu screen.

5.6.22 Image Position Initial Setting (0554)

This procedure sets up the initial image position for all
magazines.
[Selection]
[Setup and Maintenance] → [05 Printer Adjustment/
Maintenance] → [0554 Image Position Initial Setting]
1. Install the narrowest paper magazine on the
upper deck and the widest paper magazine on the
lower deck.
2. Click the [Print] button.
• After about three minutes, adjustment Prints 1
and 2 for the upper magazine and Print 3 for the
lower magazine are output.
3. Print 1: Measure the A to F dimensions and enter
them in the appropriate boxes.
Print 2: Measure the C and E dimensions and
enter them in the appropriate boxes.
Print 3: Measure the B to F dimensions and enter
them in appropriate boxes.