16.1 Replenisher Cartridge Section
3. Disconnect the connector from the sensor.
4. Release the locking tabs then remove the sensor
from the bracket.
Installation
Installation is essentially in the reverse order of removal.
16.1.3 Replenisher Cartridge Box Upper/Lower Sensor (D722/D723) Replacement
Removal
1. Remove the processor front cover
.
(See Subsection 15.1.1)
2. Remove the screw and then the sensor cover.
3. Remove the screw and then the sensor bracket.
Distributed by minilablaser.com
Screw
Sensor Cover
16-4
Locking Tabs
Sensor (D721)
Connector
Screw
Sensor Bracket
LII679
LII685
LII686