Light Source Assembly Removal/Reinstallation - FujiFilm SP-3000 Service Manual

Digital minilab
Hide thumbs Also See for SP-3000:
Table of Contents

Advertisement

8.1 Light Source Section
4. Remove the two screws and then the diffusion box
sensor bracket.
5. Open the harness clamp.
6. Remove the screw and then the diffusion box
sensor.
Installation
Installation is essentially in the reverse order of
removal.

8.1.4 Light Source Assembly Removal/Reinstallation

Removal
1. Remove the diffusion box sensor bracket
.
(See Subsection 8.1.3)
2. Disconnect the CLE2, CLE3 and CLE4
connectors from the CLE23 circuit board.
3. Open the three harness clamps.
Distributed by minilablaser.com
Screws (2)
120 Diffusion Box
Sensor (D302)
Harness Clamp
CLE2 Connector
8-5
Diffusion Box
Sensor Bracket
Screw
135 Diffusion Box
Sensor (D301)
Screw
Harness Clamps (3)
CLE4
Connector
CLE3 Connector
Z2164
8
Z2165
Z2166