FujiFilm SP-3000 Service Manual page 159

Digital minilab
Hide thumbs Also See for SP-3000:
Table of Contents

Advertisement

3.2 Messages and Actions
No.
Message
E-4611
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
E-4612
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
E-4613
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
E-4614
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
E-4615
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
E-4616
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
E-4617
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
E-4618
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
E-4619
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
NOTE 1: The refreshing backup can be restored
Distributed by minilablaser.com
Factor
SKCLE-message delivery
semaphore return error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU)
SKCLE-message delivery
semaphore reference error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU)
SKCLE-system initialization error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU)
SKCLE-task creation error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU)
SKCLE-mail box creation error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU)
SKCLE-alarm creation error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU)
SKCLE-fixed length memory pool
creation error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU)
SKCLE-variable length memory pool
creation error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU)
SKCLE-event creation error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU)
(See Section
3.4).
3-98
Actions
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.

Hide quick links: