16.3 Auto Washing and P1R Stirring System
16.3.2 Rack Auto Washing Valve/P1WR Water Replenishment Valve
(S720 to S722) Replacement
Removal
1. Remove:
• PSR pump bracket
(See Subsection 16.2.3)
• Connector cover
(See Subsection 16.2.4)
2. Disconnect the connector and open the two clamps.
3. Remove the two screws and then the valves.
4. Pinch the five hoses with the pinchcocks.
5. Loosen the hose clamps and disconnect the
hoses from the valves.
Installation
Installation is essentially in the reverse order of removal.
NOTE: Connect the hoses securely
Distributed by minilablaser.com
.
.
(See Subsection
15.2.9).
16-24
Connector
Clamps (2)
Screws (2)
Hose
Pinchcocks (5)
LII716
Valves
LII717
Clamp
LII718

Hide quick links: