6 How to Programme the Low Harmonic Drive

6.3.4 2-** Brakes

Par.
Parameter description
No. #
2-0* DC-Brake
2-00
DC Hold/Preheat Current
2-01
DC Brake Current
2-02
DC Braking Time
2-03
DC Brake Cut In Speed [RPM]
2-04
DC Brake Cut In Speed [Hz]
2-1* Brake Energy Funct.
2-10
Brake Function
2-11
Brake Resistor (ohm)
2-12
Brake Power Limit (kW)
2-13
Brake Power Monitoring
2-15
Brake Check
2-16
AC brake Max. Current
6
2-17
Over-voltage Control

6.3.5 3-** Reference / Ramps

Par.
Parameter description
No. #
3-0* Reference Limits
3-02
Minimum Reference
3-03
Maximum Reference
3-04
Reference Function
3-1* References
3-10
Preset Reference
3-11
Jog Speed [Hz]
3-13
Reference Site
3-14
Preset Relative Reference
3-15
Reference 1 Source
3-16
Reference 2 Source
3-17
Reference 3 Source
3-19
Jog Speed [RPM]
3-4* Ramp 1
3-41
Ramp 1 Ramp Up Time
3-42
Ramp 1 Ramp Down Time
3-5* Ramp 2
3-51
Ramp 2 Ramp Up Time
3-52
Ramp 2 Ramp Down Time
3-8* Other Ramps
3-80
Jog Ramp Time
3-81
Quick Stop Ramp Time
3-82
Starting Ramp Up Time
3-9* Digital Pot.Meter
3-90
Step Size
3-91
Ramp Time
3-92
Power Restore
3-93
Maximum Limit
3-94
Minimum Limit
3-95
Ramp Delay
124
VLT HVAC Low Harmonic Drive Operating In-
Default value
50 %
50 %
10.0 s
SR
SR
[0] Off
SR
SR
[0] Off
[0] Off
100.0 %
[2] Enabled
Default value
SR
SR
null
0.00 %
SR
[0] Linked to Hand / Auto
0.00 %
[1] Analog input 53
[20] Digital pot.meter
[0] No function
SR
SR
SR
SR
SR
SR
SR
SR
0.10 %
1.00 s
[0] Off
100 %
0 %
SR
®
MG.16.A1.02 - VLT
is a registered Danfoss trademark
4-set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-1
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-1
All set-ups
TRUE
-
4-set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
67
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
2 set-ups
TRUE
-2
2 set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-3
structions
Type
Uint8
Uint16
Uint16
Uint16
Uint16
Uint8
Uint32
Uint32
Uint8
Uint8
Uint32
Uint8
Type
Int32
Int32
Uint8
Int16
Uint16
Uint8
Int32
Uint8
Uint8
Uint8
Uint16
Uint32
Uint32
Uint32
Uint32
Uint32
Uint32
Uint32
Uint16
Uint32
Uint8
Int16
Int16
TimD

Advertisement

Table of Contents
loading

Table of Contents