6 How to Programme the Low Harmonic Drive

6.3.14 14-** Special Functions

Par.
Parameter description
No. #
14-0* Inverter Switching
14-00
Switching Pattern
14-01
Switching Frequency
14-03
Overmodulation
14-04
PWM Random
14-1* Mains On/Off
14-10
Mains Failure
14-11
Mains Voltage at Mains Fault
14-12
Function at Mains Imbalance
14-2* Reset Functions
14-20
Reset Mode
14-21
Automatic Restart Time
14-22
Operation Mode
6
14-23
Typecode Setting
14-25
Trip Delay at Torque Limit
14-26
Trip Delay at Inverter Fault
14-28
Production Settings
14-29
Service Code
14-3* Current Limit Ctrl.
14-30
Current Lim Ctrl, Proportional Gain
14-31
Current Lim Ctrl, Integration Time
14-32
Current Lim Ctrl, Filter Time
14-4* Energy Optimising
14-40
VT Level
14-41
AEO Minimum Magnetisation
14-42
Minimum AEO Frequency
14-43
Motor Cosphi
14-5* Environment
14-50
RFI Filter
14-51
DC Link Compensation
14-52
Fan Control
14-53
Fan Monitor
14-55
Output Filter
14-59
Actual Number of Inverter Units
14-6* Auto Derate
14-60
Function at Over Temperature
14-61
Function at Inverter Overload
14-62
Inv. Overload Derate Current
132
VLT HVAC Low Harmonic Drive Operating In-
Default value
null
null
[1] On
[0] Off
[0] No function
SR
[0] Trip
null
10 s
[0] Normal operation
null
60 s
SR
[0] No action
0 N/A
100 %
0.020 s
26.0 ms
66 %
SR
10 Hz
SR
[1] On
[1] On
[0] Auto
[1] Warning
[0] No Filter
SR
[0] Trip
[0] Trip
95 %
®
MG.16.A1.02 - VLT
is a registered Danfoss trademark
4-set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
FALSE
-
All set-ups
TRUE
-
All set-ups
FALSE
-
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
-
2 set-ups
FALSE
-
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
FALSE
0
All set-ups
FALSE
-3
All set-ups
TRUE
-4
All set-ups
FALSE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-2
1 set-up
FALSE
-
1 set-up
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
1 set-up
FALSE
-
1 set-up
FALSE
0
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
0
structions
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Int32
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16