Aastra 400 Series System Manual page 102

System functions and features as of r3.0
Hide thumbs Also See for 400 Series:
Table of Contents

Advertisement

Identification elements
Call to the Public Network via a Gateway PINX with Overflow Routing
User C (340) on PINX 2 calls user F on the public network via PINX 3 as all the availa-
ble communication channels between PINX 2 and PINX 1 are busy. PINX 3 does not
have a DDI number for user C.
The following CLIP characteristics are set in the trunk group configuration of
PINX 3:
CLIP number
= 60
NPI
=
unknown
TON
=
unknown
Fig. 39
Example 4: User C calls user F via an alternative path (excerpt from
Tab. 28
Example 4: Creating and presenting user C's CLIP number
Step
CLIP number
1
340
2
50340
3
50340
4
60
5
066 666 66 60
102
NPI
TON
PNP
level 0
PNP
level 1
PNP
level 1
Unknown
Unknown
Fig.
Description
User C → PINX 2
• There is no suitable DDI number.
PINX 2 → PINX 3
PINX 3
• There is no suitable DDI number.
PINX 3 → Exchange
• The CLIP number entered in the trunk group config-
uration is sent to the public network.
Exchange → User F
• Presentation on the terminal
System functions and features as of R3.0
35)
syd-0367/1.3 – R3.0 – 03.2013

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

470415430

Table of Contents