8. 7. 1

Structure of the PC5 output format

The PC5 format is used to output incoming and outgoing call data (ICL and OCL) on
• stand-alone communication servers
• PINX in private networks.
It is the most comprehensive PC format and is generally recommended when up-
grading with a new PC application for the acquisition and evaluation of call data.
The data is output in ASCII format in data fields. The data fields have a fixed field
length. All the data fields together form a data record. The data record begins with
a Tab and ends with a Carriage Return and Line Feed. These control characters are
output with hexadecimal values as per
Tab. 104 Control characters for separating data fields and data record
Designation
Meaning
HT
Horizontal tab
CR
Carriage Return
LF
Line Feed
A data field contains the following information:
• Data field name
• Data format
• Data field formatting
• The data field length
A data field can be identified by its position in the data record
System functions and features as of R3.0
syd-0367/1.3 – R3.0 – 03.2013
Tab.
104.
Hexadecimal value
09
0D
0A
Call logging (CL)
Usage
Start of data record
Together at the end of a data record
(CR plus LF)
(Tab.
107).