Program code
CPROTDEF(1,TRUE,3,0,–100)
G01 X–20 Y–20
X20
Y20
X–20
Y–20
EXECUTE(PROTECTB)
CPROTDEF(2,TRUE,3,–100,–150)
G01 X0 Y–10
G03 X0 Y10 J10
X0 Y–10 J–10
EXECUTE(PROTECTB)
CPROTDEF(3,TRUE,3,–150,–170)
G01 X0 Y–27,5
G03 X0 Y27,5 J27,5
X0 Y27,5 J–27,5
EXECUTE(PROTECTB)
Activation of protection zones:
NPROT(1,2,–120,60,80)
NPROT(2.2,–120,60,80)
CPROT(1,2,0,0,0)
CPROT(2,2,0,0,0)
CPROT(3,2,0,0,0)
Job planning
Programming Manual, 02/2011, 6FC5398-2BP40-1BA0
3.2 Activating/deactivating protection zones (CPROT, NPROT)
Comment
; Protection zone c–SB1
; Protection zone c–SB2
; Protection zone c–SB3
; Activate protection zone n–SB1 with
offset
; Activate protection zone n–SB2 with
offset
; Activate protection zone c–SB1 with
offset
; Activate protection zone c–SB2 with
offset
; Activate protection zone c–SB3 with
offset
Protection zones
235