Properties of the SINAUT components

1.9 SINAUT ST7cc, the add-on for WinCC

1.8.3

TIM 4R / 4RD interface adapter cable

The TIM 4R / TIM 4RD has a second serial interface X3 (combined RS-232/RS-485). The
interface (8-pin RJ-45 jack) is accessible from below.
An adapter cable is required to connect the second serial port with an external modem or
other transmission device. At one end of this cable, there is an RJ-45 plug and at the other
end, a 9-pin D-sub miniature male connector to which the normal connecting cable to the
modem or transmission device can be connected.
The adapter cable is supplied with each TIM 4R/4RD module. The adapter cable is no longer
available as separate spare part.
Table 1- 24
TIM 4R / 4RD interface adapter cable
Order no.
Description
6NH7700-0AS05
Adapter cable for connecting the 2nd serial RS-232/RS-485 port
integrated in a TIM 4R / 4RD to convert the internal plug (RJ-45)
to the 9-pin D-sub miniature male connector required externally.
Cable length 0.5 m
1.9
SINAUT ST7cc, the add-on for WinCC
1.9.1

Area of application

SINAUT ST7cc is the ideal control center system based on SIMATIC WinCC for SINAUT
ST7.
It is specially designed for event-driven and time-stamped data transmission in the SINAUT
system. It avoids the possible loss of data that can occur with cyclic polling in WinCC. It also
ensures the use of the correct event time supplied by the SINAUT stations for all WinCC
messages and archive entries. The process image integrated in ST7cc contains all process
data as well as the status of all SINAUT subscribers in the network and makes this data
available directly to WinCC for fast transfer to the process image.
The ST7cc Config configuration tool provides the user with fully integrated engineering
based on the data messages that were configured in the SINAUT stations. Configuration of
WinCC including tag management is therefore generated automatically and updated
consistently whenever changes occur.
For archives, logs and reports that meet the requirements of ATV H260 or Hirthammer, the
additional use of the WinCC add-on ACRON is advisable. ST7cc provides a configurable
data interface to these add-ons.
Along with the WinCC redundancy package, a fault-tolerant ST7cc control center can be
implemented.
68
Illustration
SINAUT ST7 station control system
System Manual, 09/2016, C79000-G8976-C178-10