Proceed as follows:
• Refer to Driver boards specifications in appendix for appropriate driver card choice.
• Remove the necessary slot covers
• Starting from the right, carefully insert the driver cards and tighten their securing
bolt.
Carefully read the labels on the driver cards and make sure the
specifications (motor type, voltage, current, etc.) match those of the
motion devices you intend to connect. Severe damage could occur if a
stage is connected to the wrong driver card.
3.4.3

Connecting to the Main

• If desired, a second protective earth line can optionally be connected to the M5
ground stud at the rear of the controller (tighten the nut at 0.5N.m).
• Terminate the provided AC line plug with a PVC main cable including an earth
conductor and with 1mm
does not include a wall plug, make sure a main switching device is installed close to
the equipment.
• The line current must be limited by a 16A fuse or circuit breaker and it must be
protected according applicable standards.
• The controller must be installed in such a way that power switch and power
connector are accessible by the user.
• Plug the AC line plug into the AC power receptacle on the rear panel and lock the
retaining clip.
• Plug the AC line cord into the AC wall-outlet or switch on the line.