Chapter 1 Maintenance
11.
System Diagnostics
The System Diagnostics runs several tests on the server.
11.1
Test Items
The following items are tested in System Diagnostics.
•
Memory
•
CPU cache memory
•
Hard disk drive
11.2
Startup and Exit of System Diagnostics
Start up System Diagnostics in the following procedure. (If the server is running, shutdown the system.)
1.
Start up EXPRESSBUILDER and select Tool menu from Boot menu.
For information on starting up EXPRESSBUILDER, refer to Chapter 3 (5. Details of EXPRESSBUILDER).
2.
Select Test and diagnostics.
Select End-User Mode (Basic) to start System Diagnostics. This process takes about three minutes.
When the diagnostics is completed, the screen display changes as shown below.
See eupro_ug_en.pdf in the \isolinux\diag folder of EXPRESSBUILDER for the End-User Mode
(Professional) feature.
Important
Before executing the System Diagnostics, be sure to disconnect the LAN
cable. Executing the System Diagnostics with the LAN cable connected may
affect the network.
Tips
No data is written to the disk on checking hard disk drives.
In case Language selection menu appears, select English.
Note
Express5800/R320c-E4, R320c-M4 Maintenance Guide (VMware)
11. System Diagnostics
83