Displaying The Status Of A Single System Component - NEC Express5800 Series Maintenance Manual

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 1 Maintenance

4.3.2 Displaying the Status of a Single System Component

Before you remove a component that is duplexed for fault tolerance, verify that it is not in a simplex state. To
verify the state of a component, type a command in the following format:
# ftsmaint ls path
For path, specify the correct value for the component, as listed in Table 1.
The value of Op State specifies whether the device is in a simplex state: the value is generally either DUPLEX
or SIMPLEX.
The following examples demonstrate some common commands and the resulting output.
In Example 2, the PCI module 1 is listed as having a State of ONLINE and an OP State of DUPLEX. The value
of SECONDARY for Reason indicates that it is operating as the backup I/O element.
Example 2. Viewing the State of the Bottom PCI module
# ftsmaint ls 11
H/W Path
Description
State
Op State
Reason
Modelx
Artwork Rev
ECO Level
Min Partner ECO Level
Serial #
Active Compat Node
Logic Revision
MTBF Policy
MTBF fault class:
Fault Count:
Last Timestamp:
Replace Threshold:
Evict Threshold:
Value:
: 11
: Combined CPU/IO
: ONLINE
: DUPLEX
: SECONDARY
: 243-634274
: 1
: 1
: 0
: CBR2BD100008
: false
: 3900042
: useThreshold
uncorrectable
0
-
0
21600
0
Express5800/R320c-E4, R320c-M4 Maintenance Guide (VMware)