(d) SNMP Alert
The SNMP Alert menu appears when you select SNMP Alert on BMC Configuration menu.
SNMP Alert
The table below shows details of parameters and their default value.
Item
SNMP Alert
SNMP Alert
Computer Name
Community Name
Alert Process
Alert Acknowledge
Alert Retry Count
Alert Timeout
Alert Reciever1
IP Address1
Alert Reciever2
IP Address2
Alert Reciever3
IP Address3
Alert Level
Alert Level
Alert Test
*1: When PEF (Platform Event Filter) is set to "Disable" in Miscellaneous menu, SNMP alert is disabled.
*2: Up to 16 alphanumeric characters are accepted.
*3: Can be specified only when Alert Acknowledge is set to "Enable".
*4: When SNMP Alert is enabled, at least one alert receiver should be enabled.
*5: Can be specified only when each Alert Receiver is set to "Enable".
*6: Be sure to perform Alert Test after all the parameters are configured appropriately. Alert feature may fail
depending on configuration made for network or alert receiver.
SNMP Alert
Alert Level
Alert Test
Help
Return to the previous menu
Previous menu:[ESC]
SNMP Alert menu
Enable or disable SNMP Alert.
Specify the Computer Name.
Specify the Community Name.
Select One Alert Receiver or All Alert Receiver for Alert Process.
Enable or disable Alert Acknowledge.
Specify the count of Alert retry.
Specify the timeout period (in seconds) for alert.
Enable or disable primary receiver.
Specify the IP Address of primary receiver.
Enable or disable secondary receiver.
Specify the IP Address of secondary receiver.
Enable or disable tertiary receiver.
Specify the IP Address of tertiary receiver.
Specify the kind of event to alert.
Error
: When "Error" is detected in each sensor type, the alert is sent to
the checked address.
Error, Warning
: When "Error" or "Warning" is detected in each sensor type, the
alert is sent to the checked address.
Error, Warning, Information
: When "Error", "Warning" or "Information" is detected in each
sensor type, the alert is sent to the checked address.
Separate Setting
: You can arbitrarily select the event to alert in each sensor type.
Execute a test by SNMP alert.
Express5800/R320c-E4, R320c-M4 Maintenance Guide (VMware)
Description
*1
*2
*2
*3
*3
*4
*5
*4
*5
*4
*5
*6
2. BMC Configuration
Default Value
Disable
Blank
Public
One
Alert
Receiver
Enable
3
6
Enable
0.0.0.0
Disable
0.0.0.0
Disable
0.0.0.0
Error, Warning