NEC Express5800 Series Maintenance Manual page 51

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 1 Maintenance
Error Message
C061
1st SMBus device Error
detected.
C062
2nd SMBus device Error
detected.
C063
3rd SMBus device Error
detected.
C064
4th SMBus device Error
detected.
C065
5th SMBus device Error
detected.
C066
6th SMBus device Error
detected.
C067
7th SMBus device Error
detected.
C101
BMC Memory Test
Failed..
C102
BMC Firmware Code
Area CRC check
Failed.
C103
BMC core hardware
failure.
C104
BMC IBF or OBF check
failed.
C105
BMC SEL area full.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC
FRU corrupted.
BMC SDR Repository empty. An error was detected on BMC SDR.
C10E
C10F
IPMB signal lines do not
respond.
BMC FRU device failure. An error was detected in FRU that
C110
C111
BMC SDR Repository
failure.
BMC SEL device failure. Device failure was detected in BMC
C112
C113
BMC RAM test error.
BMC Fatal hardware error. A hardware error was detected in BMC.
C114
C115
Management controller
not responding
C116
Private I2C bus not
responding.
C117
BMC internal exception
C118
BMC A/D timeout error.
SDR repository corrupt. BMC error or illegal SDR data was
C119
C11A
SEL corrupt.
Cause
An error was detected on 1st SM Bus.
An error was detected on 2nd SM Bus.
An error was detected on 3rd SM Bus.
An error was detected on 4th SM Bus.
An error was detected on 5th SM Bus.
An error was detected on 6th SM Bus.
An error was detected on 7th SM Bus.
An error was detected on BMC.
An error was detected while accessing
BMC.
There is not enough space to store the
system event log.
An illegality was detected while
updating BMC firmware.
An illegality was detected in FRU
containing the device information.
Failure of Satellite Management
Controller was detected.
contains device information.
Failure was detected in SROM that
stores the SDR.
SEL.
An error was detected in BMC RAM.
Management controller does not
respond.
Private I2C bus does not respond.
BMC internal error was detected.
BMC A/D timeout error was detected.
detected.
BMC error or illegal system event log
data was detected.
Express5800/R320c-E4, R320c-M4 Maintenance Guide (VMware)
Solution
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your sales
representative.
Run the Off-line Tool and delete the event logs.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your sales
representative.
Update the BMC firmware.
If the same error is detected repeatedly,
contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your sales
representative.