Chapter 1 Maintenance
Clearing a password
1.
Disconnect AC power cords from CPU/IO modules 0 and 1.
2.
Remove CPU/IO module 0, and remove its top cover.
Refer to Chapter 2 (5.4 CPU/IO Module).
3.
Confirm the position of Clear Password Jumper.
4.
Change jumper switch to "PASS CLR" position.
5.
Assemble the CPU/IO module 0.
6.
Connect AC power cords to CPU/IO modules 0 and 1 at the same time.
7.
Confirm that PRIMARY LED of CPU/IO module 0 lights after a while.
If PRIMARY LED of CPU/IO module 1 lights, disconnect AC power cords from both CPU/IO modules,
wait for 30 seconds, and connect them at the same time.
8.
When the POWER LEDs on CPU/IO modules 0 and 1 starts blinking, press the POWER switch to turn
on the server.
9.
If the following warning message appears, press the POWER switch to power off the server.
(POST proceeds even when the warning message is displayed.)
WARING
8007:SETUP Menu Password cleared by Jumper.
10. Disconnect AC power cords from CPU/IO modules 0 and 1.
11. Remove CPU/IO module 0, and remove its top cover.
12. Change jumper switch setting to its original position (Protect).
13. Assemble the CPU/IO module 0.
14. Connect AC power cords to CPU/IO modules 0 and 1.
82
Express5800/R320c-E4, R320c-M4 Maintenance Guide (VMware)