It may take approximately two hours of operation for the burn media to achieve their full flame
pattern and glow. During the initial burning-in period, some smoke and smell may be experienced.
The appliance should run on a high setting in a well ventilated room until these dissipate. It is
important to check the flame pattern during this time.
Abnormal flame pattern
Abnormal flame performance and/or pattern can indicate a problem with the fire, such as blocked
gas injectors, flame rod obstruction, or that the burn media has shifted. Some warning signs that
could indicate a problem:
Unusual smell from the fire
-
Continued difficulty or delay in establishing a flame
-
Flame appears very short or very long
-
Flame only burns part way across the burner
-
Severe soot building up on the inside of the glass door
-
Flame pattern should look like this (may vary slightly depending on gas type)
Linear 800 FlameTech log
set
Linear 1000 log set
Linear 1000 modern media (glass)
Linear 1500 log set
26 | Linear installation guide 13563-B 02-19
Linear 800 standard log set
Important
It is the responsibility of the installer
to check that under normal conditions
of the appliance, all flue gases are
exhausted to the outside atmosphere,
and that there is no spillage of
combustion gases into the room.
If the appliance cannot be made
to perform correctly please contact
Rinnai.
Linear 1500 crushed glass is not
shown, the flame pattern will be the
same as the 1000 model shown here.