Specification

Inbuilt power flued convection fan fire operated by a simple infra-red remote, or by the Rinnai Wi-
Fi app that allows full thermostatic control as well as other features such as timers. Different burn
media options available.
Specification summary
Input
800
14-35 MJ/h
800FT
14-35 MJ/h
1000
14-35 MJ/h
1500
14-40 MJ/h 3.2-9.2 kW 78-133 m
Efficiency
= > 75% (all models on high)
Gas type
= NG or ULPG
* Will vary according to gas type and flue configuration
** Will vary depending on geographical location in NZ
Suitability
Ideal for living rooms and open plan areas.
Versatile power flue system makes for easy
installation in almost any living space, including
bedrooms.
The Linear is ideal for a new build installation
into a false (mock) chimney.
Installation considerations
Room size—smaller rooms will heat up quickly,
and due to the efficiency of the appliance, if in
thermostatic mode, will reduce to a low flame
profile.
Installation of the Linear higher up the wall, in
some room configurations, can create draughts
due the convection air being pushed out from
the top of the appliance.
Cavity ventilation at the bottom and top of the
installation cavity, refer p. 12 for further details.
Convection fan
2-speed fan. Heat is distributed from the top of
the appliance.
Data plate
1500
Base of the combustion chamber towards the
LHS, between the gas control and convection
fan access panel.
800/1000
Base of the combustion chamber, LHS, on the
convection fan access panel.
Output*
Heating area**
3.2-8.0 kW 62-106 m
2
3.3-8.3 kW 62-106 m
2
3.2-8.0 kW 67-120 m
2
2
Gas connection
½ " BSP, the gas supply terminates inside the
heater—lower left hand side of the appliance.
Ignition
Continuous spark electronic ignition.
Noise level
37-45 dB(A)
Power flue
Inner 50 mm, outer 70~80 mm. Appliance must
be installed with a Rinnai flue system.
Power consumption/electrical supply
High
= 90 W
Standby
= <8 W
The Linear has a 1.5 m power cord with a three
pin plug supplied. The power cord passes
through a slot in the right hand side of the
appliance.
Safety devices
Flame failure sensing system, pressure relief,
overheat safety switch, air temperature sensor,
thermal fuse, overcurrent fuse, and spark
detection.
Temperature control
The Linear can be operated using the basic
infra-red remote, or for more features, such as
timers and thermostatic control, using Rinnai's
Wi-Fi fireplace controller app.
Weights
Unit
100 kg
800
100 kg
1000
110 kg
1500
Linear installation guide 13563-B 02-19 | 5
Packaged
120 kg
125 kg
140 kg