IBM Power Systems EMX0 PCIe Gen3 Manual page 61

Chassis management card for the i/o expansion drawer
Hide thumbs Also See for Power Systems EMX0 PCIe Gen3:
Table of Contents

Advertisement

2. On the IVM, open Manage Serviceable Events and look at existing serviceable events.
3. Are there any service action events that are open?
v Yes: Continue with the next step.
v No: If the system attention LED is still on, turn off the LED as described in "Activating and
deactivating LEDs" on page 47. Return the system to the customer. This completes the repair.
4. Record the list of open service action events.
5. From the list of serviceable events recorded in step 4, complete steps 6 - 30 on page 46 for each open
service action event.
6. Determine the error class of the serviceable event. Record it for future use.
7. Examine the details of the open service action event.
Is the error code associated with this service action event the same as recorded in step 1 on page 44?
v Yes: Go to step 11.
v No: Continue with the next step.
8. Examine the FRU list of the service action event. Are any FRUs listed for the service action event?
v Yes: Continue with the next step.
v No: Go to step 11.
9. Is the FRU list identical that is, the same FRUs, same number of FRUs, and same order of FRUs) to
the FRU list of the error code recorded in step 1 on page 44?
v Yes: Go to step 11.
v No: Continue with the next step.
10. Is the FRU you replaced and recorded in step 1 on page 44 in the list of FRUs for this service action
event?
v Yes: Continue with the next step.
v No: Go to step 30 on page 46.
Note: Some service action events remain open when you leave this MAP. Further service actions
might be required to complete the repair.
11. Examine the details of this service action event, and record the partitions involved in this service
action event for use in a later step.
12. Is the error code associated with this service action event of the form A11-xxx or A01-xxx?
v Yes: Continue with the next step.
v No: Go to step 17.
13. Have you begun a list of Axx partitions from prior service action events that you processed in this
maintenance analysis procedure (MAP)?
v Yes: Go to step 15.
v No: Continue with the next step.
14. Begin a new list of Axx partitions by copying the list of partitions obtained in step 11. Go to step 16.
15. Add the partition list obtained in step 11 to the existing list of Axx partitions obtained from
processing previous service action events in this MAP.
16. Remove all entries in the list of all partitions you recorded in step 11. If you are referred to the list of
partitions obtained in step 11 in future steps, the list is empty. Go to step 17.
17. Select and highlight the service action event from the Manage Serviceable Events window.
18. Click Close Event.
19. Add comments for the serviceable event. Include any unique additional information. Click OK.
20. Add or update the FRU information:
Did you replace, add, or modify a FRU of the open service action event?
v Yes: Continue with the next step.
Common procedures for removing or replacing the chassis management card
45