IBM Power Systems EMX0 PCIe Gen3 Manual page 58

Chassis management card for the i/o expansion drawer
Hide thumbs Also See for Power Systems EMX0 PCIe Gen3:
Table of Contents

Advertisement

For instructions about running stand-alone diagnostics from a NIM server, go to Running the
stand-alone diagnostics from a Network Installation Management server.
Did you encounter any problems?
v Yes: Go to Problem analysis.
v No: Continue with the next step.
6. The system hardware is functioning correctly.
If the system attention LED is still on, turn off the LED as described in "Activating and deactivating
LEDs" on page 47.
This completes the repair.
Note: If, during the processing of the list of open service action events, some service action events
remained open, further service actions might be required to complete the repair.
Return the server to the state that the customer normally uses, such as IPL type, IPL mode, and the
way the system is configured or partitioned. This might require you to reboot the operating system.
7. Complete the following steps:
a. Restart the system.
b. Wait until the AIX operating system login prompt is displayed or until system activity on the
operator panel or display has stopped.
Did the AIX Login Prompt display?
v Yes: Continue with the next step.
v No: Go to Problem analysis.
8. If the Resource Repair Action menu is already displayed, go to 12 on page 43; otherwise, complete
the following steps:
a. Log into the operating system, either with root authority (if needed, ask the customer to enter the
password) or use the CE login.
b. Enter the diag -a command and check for missing resources. Follow any instructions that are
displayed. If a system request number (SRN) is displayed, suspect a loose card or connection. If
no instructions are displayed, no resources were detected as missing. Continue with step 9.
9. Complete the following steps:
a. Enter diag at the command prompt and press Enter.
b. Select the Diagnostics Routines option.
c. When the Diagnostic Mode Selection menu is displayed, select Problem determination.
d. When the Advanced Diagnostic Selection menu is displayed, select the All Resources option.
Alternatively, test the FRUs you exchanged and any devices that are attached to the FRUs you
exchanged by selecting the diagnostics for the individual FRU.
Did the Resource Repair Action menu (801015) display?
v Yes: Go to step 13 on page 43.
v No: Continue with the next step.
10. Did the TESTING COMPLETE, no trouble was found menu (801010) display?
v Yes: Continue with the next step.
v No: There is still a problem. Go to Problem analysis.
11. Select the Log Repair Action option, if not previously logged, in the TASK SELECTION menu to
update the AIX error log. If the repair action was reseating a cable or adapter, select the resource
associated with that repair action.
If the resource associated with your action is not displayed on the resource list, select sysplanar0.
Note: If the check log indicator is on, this will set it back to the normal state. Go to step 14 on page
43.
42
Power Systems: Chassis management card for the EMX0 PCIe Gen3 I/O expansion drawer