Set Up The Dry Contact Alerts - Honeywell Home THX9321 Prestige 2.0 Manual

Table of Contents

Advertisement

®
THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
The thermostat will call for the fan and lockout all other
equipment until the dry contact device senses air flow
again or the feature is unconfigured at the thermostat.
Custom Alert
Allows the dealer to enter a custom alert to be displayed
when a dry contact device is activated. For example, a float
switch can detect when your sump pump is not working.
Get Connected Alert
This alert will inform homeowners about the RedLINK
Internet Gateway so they can control their thermostat
using the My Total Connect Comfort app from their phone,
tablet, or PC. The alert only appears if the thermostat has
been installed without a RedLINK internet gateway
enrolled for 14 consecutive days. The alert can be snoozed
or permanently dismissed by the homeowner.
MULTIPLE DRY CONTACT DEVICES
ON ONE SET OF TERMINALS
1. Wire the dry contact device to S1, S2, S3, or S4 termi-
nals at the EIM.
2. Enter Installer Setup (see "Installer Options" begin-
ning on page 21).
3. Dry Contacts are selected at ISU 6000. Select the
appropriate Dry Contact(s) and press Next.
Fig. 188.
68-0311—08
®
IAQ WITH EIM
ONE DRY CONTACT DEVICE
EIM
S4
S4
S3
S3
Fig. 187. Wiring dry contact devices.

Set Up the Dry Contact Alerts

WARNING
Equipment Damage Hazard.
Do not apply power to S1, S2, S3, or S4 terminals. Do
not connect a temperature sensor to the S1, S2, S3,
or S4 terminals if setup for a dry contact device.
IMPORTANT
The dry contact device must be rated for low volt-
age.
NOTE: You can connect multiple Dry Contact devices in
parallel to the S1, S2, S3, or S4 terminals.
You can connect the S1, S2, S3, or S4 terminals on the EIM
to a dry contact device to display an alert. Dry contact
alerts include Full Drain Pan, Dirty Filter, Water Leak,
System Shutdown, Service Needed, Fan Failure and
Custom Alert. A dry contact device can be normally open
(shown in diagram) or normally closed.
ONE DRY CONTACT DEVICE
EIM
MULTIPLE DRY CONTACT DEVICES
ON ONE SET OF TERMINALS
4. Select the terminals wired to the Dry Contact device,
and press Next.
94
Fig. 189.

Hide quick links: