Number
Name
None
13170
Defrost Cycle
1 to 60 minutes (in 1 minute
increments)
1 to 5
13180
Delta T Alert
Sensitivity
No
13190
Display Delta T Alerts
Yes
to User
12 hour
14000
Clock Format
24 hour
Off
14010
Daylight Saving Time
On
-3° F to 3° F (in 1° F increments)
14020
Indoor Temperature
Display Offset
-12% to 12% (in 1% increments)
14020
Indoor Humidity
Display Offset
[Dealer Name]
15000
Dealer Name
[Dealer Phone]
15000
Dealer Phone
[Dealer Email Address]
15010
Dealer Email Address
[Dealer Website]
15010
Dealer Website
[Dealer Message]
15020
Dealer Message
68-0311—08
®
IAQ WITH EIM
Table 4. Installer Setup (ISU) Table. (Continued)
Settings
Default
10
3
Yes
12
On
0° F
0%
None
None
None
None
None
64
Residential,
Commercial
Requires
or Both
EIM
Both
Yes
This ISU is only displayed if ISU 2010 Heating
Equipment Type is Air to Air Heat Pump.
Press the up/down arrows to set the maximum
time duration of a defrost cycle. Check the heat
pump documentation for the defrost cycle time.
Note: The diagnostic algorithm detects when
the system goes into defrost based on the
measured Delta T of the system. When the
thermostat detects this change in temperature,
the thermostat will not compare Delta T to the
Minimum and Maximum Delta T Fault Limits.
After the defrost cycle has ended, the
thermostat will resume monitoring Delta T of
the system.
Both
Yes
See "Delta T Alert Sensitivity (ISU 13180)."
beginning on page 88.
Both
Yes
No: The thermostat does NOT display a Delta T
alert to the user when a Delta T alert is entered
into the log.
Yes: The thermostat displays a Delta T alert to
the user when a Delta T alert is entered into the
log.
See "Delta T Alerts" beginning on page 88.
Both
No
Both
No
Set to Off in areas that do not follow Daylight
Saving Time.
Both
No
0° F - No difference in displayed temperature
and the actual room temperature.
The thermostat displays up to 3°F (1.5°C)
lower or higher than the actual measured
temperature.
Both
No
0% - No difference in displayed humidity and
the actual room humidity.
The thermostat displays up to 12% lower or
higher than the actual measured humidity.
Both
No
Both
No
Both
No
Both
No
Both
No