THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
ISU
Installer Setup
Number
Name
Minimum Setting
13050
Allow Heat Delta T
Diagnostics when
Indoor Temperature
No Limit
is [Indoor
35° F to 115° F (in 5° F
Temperature Range]
increments)
Maximum Setting
13050
No Limit
40° F to 120° F (in 5° F
increments)
Minimum Setting
13060
Allow Heat Delta T
Diagnostics when
Indoor Humidity is
No Limit
[Indoor Humidity
0% to 95% (in 5% increments)
Range]
Maximum Setting
13060
No Limit
5% to 100% (in 5% increments)
Minimum Setting
13070
Allow Heat Delta T
Diagnostics when
Outdoor
No Limit
Temperature is
-50° F to 135° F (in 5° F
[Outdoor
increments)
Temperature Range]
Maximum Setting
13070
No Limit
-45° F to 140° F (in 5° F
increments)
Minimum Setting
13080
Allow Heat Delta T
Diagnostics when
Outdoor Humidity is
No Limit
[Outdoor Humidity
0% to 95% (in 5% increments)
Range]
Maximum Setting
13080
No Limit
5% to 100% (in 5% increments)
Minimum Setting
13090
Allow Backup Heat
Delta T Diagnostics
when Indoor
No Limit
Temperature is
35° F to 115° F (in 5° F
[Indoor Temperature
increments)
Range]
Maximum Setting
13090
No Limit
40° F to 120° F (in 5° F
increments)
Minimum Setting
13100
Allow Backup Heat
Delta T Diagnostics
when Indoor
No Limit
Humidity is [Indoor
0% to 95% (in 5% increments)
Humidity Range]
Maximum Setting
13100
No Limit
5% to 100% (in 5% increments)
68-0311—08
®
IAQ WITH EIM
Table 4. Installer Setup (ISU) Table. (Continued)
Settings
Default
No Limit
(Always)
No Limit
(Always)
No Limit
(Always)
No Limit
(Always)
No Limit
(Always)
No Limit
(Always)
No Limit
(Always)
No Limit
(Always)
No Limit
(Always)
No Limit
(Always)
No Limit
(Always)
No Limit
(Always)
62
Residential,
Commercial
Requires
or Both
EIM
Both
Yes
This ISU only applies to Heating.
This ISU is only displayed when ISU 13015 Set
Advanced Diagnostic Options is set to Yes.
The thermostat monitors Delta T of the system
Both
Yes
ONLY when the indoor temperature is within a
certain range. Set to No Limit to monitor Delta
T during all indoor temperature conditions.
Both
Yes
This ISU only applies to Heating.
This ISU is only displayed when ISU 13015 Set
Advanced Diagnostic Options is set to Yes.
Both
Yes
The thermostat monitors Delta T of the system
ONLY when the indoor humidity is within a
certain range. Set to No Limit to monitor Delta
T during all indoor humidity conditions.
Both
Yes
This ISU only applies to Heating.
This ISU is only displayed when ISU 13015 Set
Advanced Diagnostic Options is set to Yes.
The thermostat monitors Delta T of the system
Both
Yes
ONLY when the outdoor temperature is within a
certain range. Set to No Limit to monitor Delta
T during all outdoor temperature conditions.
Both
Yes
This ISU only applies to Heating.
This ISU is only displayed when ISU 13015 Set
Advanced Diagnostic Options is set to Yes.
Both
Yes
The thermostat monitors Delta T of the system
ONLY when the outdoor humidity is within a
certain range. Set to No Limit to monitor Delta
T during all outdoor humidity conditions.
Both
Yes
This ISU only applies to Backup Heat.
This ISU is only displayed when ISU 13015 Set
Advanced Diagnostic Options is set to Yes.
The thermostat monitors Delta T of the system
Both
Yes
ONLY when the indoor temperature is within a
certain range. Set to No Limit to monitor Delta
T during all indoor temperature conditions.
Both
Yes
This ISU only applies to Backup Heat.
This ISU is only displayed when ISU 13015 Set
Advanced Diagnostic Options is set to Yes.
Both
Yes
The thermostat monitors Delta T of the system
ONLY when the indoor humidity is within a
certain range. Set to No Limit to monitor Delta
T during all indoor humidity conditions.