Honeywell Home THX9321 Prestige 2.0 Manual page 54

Table of Contents

Advertisement

®
THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
ISU
Installer Setup
Number
Name
Full drain pan
8095
Humidity Lockout
Water leak
Dry Contact
None
Off
8100
Clean Tank / Water
Filter Replacement
60 Run Time Days
Reminder
90 Run Time Days
6 Calendar Months
12 Calendar Months
Off
8100
Humidifier Pad
60 Run Time Days
Replacement
Reminder
90 Run Time Days
6 Calendar Months
12 Calendar Months
Residential:
9000
Dehumidification
Equipment
None
A/C with Low Speed Fan
A/C with High Speed Fan
Whole House Dehumidifier
Commercial:
None
A/C with Low Speed Fan
A/C with High Speed Fan
Hot Gas Bypass
Dehumidifier
Low speed fan with cool stage 1
9005
Dehumidification
only
Fan Speed Priority
Low speed fan always
User selectable
Thermostat (Internal)
9010
Which Sensor will be
used for
Sensor Name (Remote)
Dehumidification
Sensor Name (Remote)
Control?
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
(Up to 6 Remote Sensors)
Humidification Sensor
9020
Which Indoor
Humidity Sensor
Dehumidification Sensor
should be displayed
on the Home Screen?
68-0311—08
®
IAQ WITH EIM
Table 4. Installer Setup (ISU) Table. (Continued)
Settings
Default
None
Off
Off
None
Low speed fan
with cool stage 1
only
Thermostat
(Internal)
Humidification
Sensor
54
Residential,
Commercial
Requires
or Both
EIM
Both
Yes
If the selected alert (full drain pan or water
leak) is detected, the thermostat will lock out
the call for humidity. This is only available if the
thermostat is configured to control a humidifier
and is set up to do a full drain pan and/or water
leak dry contact alert.
Both
No
This ISU is only displayed if ISU 8000
Humidifier Type is Steam.
Run Time Days are not shown if ISU 8000
Humidifier Type is set to None.
Both
No
This ISU is only displayed if ISU 8000
Humidifier Type is Bypass or Fan Powered.
Run Time Days are not shown if ISU 8000
Humidifier Type is set to None.
Both
No
See "Dehumidification - Residential" beginning
on page 103 or "Dehumidification -
Commercial" beginning on page 108.
Both
Yes
See "Dehumidification Fan Speed Priority"
beginning on page 103 for description.
Both
No
Select a sensor to control dehumidification
(thermostat or an optional remote sensor). If
multiple sensors are installed, you can use a
different sensor for humidification control. See
"Dehumidification Control" beginning on
page 130.
Note: Humidity sensing cannot be averaged.
Both
No
This ISU is only displayed when separate
humidity sensors are used to control
humidification and dehumidification. Only one
of the sensors can be displayed on the home
screen. Select either the Humidification Sensor
or the Dehumidification Sensor.
Notes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents