THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
ISU
Installer Setup
Number
Name
Off
10130
Ventilation High Dew
Point Lockout
65° F to 85° F (in 5° F increments)
Off
10140
Lockout Ventilation
On
on Humidification or
Dehumidification
Calls
Off
10160
Ventilate on High
Indoor Humidity
On (Heat Mode Only)
Off
10170
Ventilator Core
3, 6, 9, 12 Calendar Months
Cleaning Reminder
Off
10170
Ventilator Filter
3, 6, 9, 12 Calendar Months
Cleaning Reminder
0, 1, 2
11000
Number of UV
Devices
Off, 6, 12, 24 Calendar Months
11050
UV Bulb 1
Replacement
Reminder
Note: "1" is not
displayed if there is
only 1 UV Bulb
Off, 6, 12, 24 Calendar Months
11050
UV Bulb 2
Replacement
Reminder
View / Edit Custom Reminders
12000
Installer Custom
Reminders
Add Custom Reminders
68-0311—08
®
IAQ WITH EIM
Table 4. Installer Setup (ISU) Table. (Continued)
Settings
Default
Off
Off
On (Heat Mode
Only)
Off
Off
0
Off
Off
None
60
Residential,
Commercial
Requires
or Both
EIM
Both
No
Requires a Wireless Outdoor Sensor (sense
outdoor humidity).
This ISU is only displayed when ISU 10000
Ventilation Type is set to ERV / HRV or Fresh Air
Damper.
See "Ventilation — Outdoor Condition Lockouts
(ISU 10130)" beginning on page 112.
Both
No
This feature is used to help reach the user's
desired humidity level by not allowing the
ventilation equipment to run during a call for
humidification or dehumidification.
Off: Ventilation is allowed to run during a call
for humidification or dehumidification.
On: Ventilation is NOT allowed to run during a
call for humidification or dehumidification.
Both
No
This ISU is only displayed when ISU 10000
Ventilation Type is set to ERV / HRV.
Off: The humidity level has no effect on
ventilation.
On: The thermostat removes excess humidity
by turning on the ventilator when the indoor
humidity rises 10% above the user's
humidification setting. The thermostat must be
in the heat mode to ventilate on high humidity.
Both
No
Both
No
Both
No
Press the up/down arrows to select the number
of UV devices installed in the system. Some
systems may have two UV devices, one for the
A-Coil and another for Air Treatment. A
replacement reminder can be setup for each
one. Select 0 if no UV devices are installed.
Both
No
Both
No
Both
No
See "Customizable Reminders" beginning on
page 117.
Notes