BRP I-Command Evinrude Etec Series User Manual page 14

Table of Contents

Advertisement

Terminating Resistors
Terminating resistors are required for accurate network transmissions. Net-
works must be assembled with one terminator installed at each end of the
I-Command network. See the "Network Specification Diagram" on page 10.
Tee-Connectors and Buss Cables
Tee-connectors provide each device access to the network. Single Tee-con-
nectors have two buss connectors and one device connector. Double
Tee-connectors have two buss connectors and two device connectors. Net-
work devices must be connected to the device connector of the Tee-connec-
tor.
Tee-connectors can be installed at the end of a network. Connect a network
buss cable to one side and a terminator into the other.
Multiple Tee-connectors can be installed in the middle or the end of a net-
work. Use network buss cables to connect Tee-connectors or multiple
Tee-connectors. See the "Network Specification Diagram" on page 10.
2
1
1. Female terminating resistor (sockets)
2. Male terminating resistor (pins)
1
2
BUSS
1
2
BUSS
1. Device connector
2. Buss connector
2
2
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents