Gauge Flashes Four Dashes - BRP I-Command Evinrude Etec Series User Manual

Table of Contents

Advertisement

Gauge Flashes Four Dashes

1. If the I-Command digital display flashes four dashes (– – – –) it indicates
the gauge is not receiving signal from one or more devices.
2. A Network Test Kit, P/N 765023 is available to assist in troubleshooting
network problems. If desired, order the tester kit through your dealer.
Troubleshoot network problems using process of elimination.
•Make sure devices are configured. See "Advanced Setup and Opera-
tion" on page 57.
•If multiple displays are flashing, check common items such as cables
and tees.
•Remove components from the network one at a time to isolate which
one may have failed.
•Look for damaged parts. Check connectors for corrosion.
•Swap known good components (sensor, cables or tees) to isolate the
faulty component.
•Reconnect the good component to the network and the remove the next
one in line.
•Continue this process for each device, cable or tee connector on the
network until the faulty part is found.
Note: Once components are reconnected, if the digital display continues to
flash, turn power to the network OFF and back ON to reset the gauge(s).
20
70
10
35
Volts
Volts
13.6
56.2
0
0
BATT:V
ALR:V
WTR: T
WTR:P
– – – –
20
70
– – – –
°F
psi
10
35
x10
0
0
M E N U
1
+
+
+
+
+
BUSS
BUSS
2
86

Hide quick links:

Advertisement

Table of Contents
loading