Planet IPM-4220 User Manual

Planet IPM-4220 User Manual

Ip-based 4//8-port switched power manager

Advertisement

IP-based 4-/8-port Switched
Power Manager
IPM-4220/IPM-8220

Advertisement

Table of Contents
loading

Summary of Contents for Planet IPM-4220

  • Page 1 IP-based 4-/8-port Switched Power Manager IPM-4220/IPM-8220...
  • Page 2 IPM-4220 / IPM-8220 Copyright Copyright  2016 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of PLANET.
  • Page 3 Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately. Revision User’s Manual of PLANET IP-based 4-/8-port Switched Power Manager Model: IPM-4220/IPM-8220 Rev: 1.00 (July, 2016) Part No. EM-IPM-4220_8220_v1.0...
  • Page 4: Table Of Contents

    Network Connection ....................24 Setup Wizard ......................24 Chapter 4. Web-based Management ................. 28 Monitor ........................28 4.1.1 Infeed ..................... 28 4.1.2 Outlet (For IPM-4220) ................30 4.1.3 Outlet (For IPM-8220) ................32 4.1.4 Temperature ................... 35 4.1.5 RH Sensor ..................... 37 4.1.6 Daisy Chain....................
  • Page 5 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 4.3.4 SNMP ..................... 49 4.3.5 Syslog ....................50 4.3.6 Serial Port (UART) ................. 51 4.3.7 Peripheral Parameters ................52 4.3.8 Other ...................... 55 Firewall ........................56 4.4.1 IP Filter ....................56 4.4.2...
  • Page 6: Chapter 1. Product Introduction

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Chapter 1. Product Introduction 1.1 Package Contents The package should contain the following:  1 x Switched IPM  1 x Quick Installation Guide  1 x Power cord  1 x Quick Rack-mounting Kit Installation Guide (For IPM-8220)
  • Page 7: Overview

    Intelligent Power Management The IPM-4220/8220 offers 4/8 power outlets, each of which can be controlled or monitored individually by the console or SNMP manager software or web interfaces. They allow users to access, configure, and manage many networking devices at the same time from remote locations to save valuable time.
  • Page 8 Securing you against the risk of getting the entire circuit cut off, commonly happened with ordinary power distribution units (PDUs), when there is overloaded power, PLANET PDU, with a built-in circuit breaker and reset switch, ensures the stability of power distribution among its equipment. Its 16-amp...
  • Page 9 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Energy and Cost Saving You can also check the current energy consumption in your office within the configuration interface of the IPM-4220/8220. It helps you reduce energy consumption, thus saving expenses on utilities.
  • Page 10: Features

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 1.3 Features  Hardware ■ Desktop/1U rack-mount size design ■ IEC outlet models ■ 4/8 power outlets that support real-time current image monitoring ■ 4/8 LEDs show power status for each power outlet ■...
  • Page 11 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220  Security ■ Web page supports 1024-bit SSL security encryption transmission ■ Supports Secure Socket Layer V3 and Secure Shell V1 protocols ■ Administrator and multiple users with password protection for double-layer security ■...
  • Page 12: Specifications

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 1.4 Specifications Product IP-based 4-/8-port Switched Power Manager Hardware Specifications IPM-4220 IPM-8220 Outlet Power Port Inlet Power Port Sensor Port 1 RJ11-type port, 6P Com Port 2 RJ45-type ports Network Connector...
  • Page 13 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Management User Account General/Manage/Administrator Management Utility Web browser, SNMP software, Windows-based utility, Telnet Security IP filter/MAC filter/Secure 128-bit SSL encryption Standards Conformance IEEE 802.3 10BASE-T Computer Interface IEEE 802.3u 10/100BASE-TX Regulatory Compliance...
  • Page 14: Chapter 2. Hardware Interface

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Chapter 2. Hardware Interface 2.1 Physical Descriptions IPM-4220 Rear Panel IPM-4220 Front Panel System Indicating Light Slow flashing: Normal operating Rapid flashing: Normal updating Reset and Warning Indicating Light Temperature/Humidity Port for IPM-ESB Connection...
  • Page 15 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Power Outlet Note: The maximum output current is 16 amps. LCD Panel: To display total current and IP Switch/Set button Provide LCD panel in order to switch the total current and IP; set alarm current...
  • Page 16 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220  LCD menu shows the total current.  Hold the Switch/Set button for 3 seconds (until a long beep is heard) to enter alarm current setting.  Press the Switch/Set button to increase the alarm current by 0.5A in each press.
  • Page 17 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 IPM-8220 Rear Panel IPM-8220 Front Panel System Indicating Light Slow flashing: Normal operating Rapid flashing: Normal updating Reset and Warning Indicating Light Temperature/Humidity Port for IPM-ESB Connection Reset Button RJ45 Ethernet Port...
  • Page 18 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 power switch control and IP; set alarm current Buzzer Alarm Indicating Light Lights remaining lit: Alarm has occurred Slow flashing: There is current overloading Power Outlet Indicating Light IPM-8220 Current Panel Operation When the LCD panel only displays figures and the sign of "A (AMP)", it means total current.
  • Page 19 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220  Press the Set button to show the voltage information.  Press the Set button to show the maximum current record of all branches (branch 1 and branch 2).  Hold the Set button for 3 seconds (until a long beep is heard) to adjust to a zero point.
  • Page 20: Product Concatenation

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 operated through the panel. Please go to the Peripheral of web UI and check the setting. IPM-8220 IP Panel Operation Press the Switch button to show words like "IP"  Press the Set button to switch the display of each IP address.
  • Page 21: Installation Precautions

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 2. For the main power supply control of the Switched IPM, set the UART type as daisy chain. 3. For the secondary power supply control of the Switched IPM, set the UART type as API. The power outlet of the main and secondary remote power control devices can be set to determine the power outlet requiring concatenation.
  • Page 22: Hardware Installation

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220  Use the attachments/accessories specified by the manufacturer only.  Please avoid any items or liquids entering the device because their contact with dangerous voltage points or short-circuit parts may cause a fire or electric shock.
  • Page 23: Initial Utility Installation

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 2.5 Initial Utility Installation PLANET “IP Search” is a software utility used to search the IP Metered PDU product on a network quickly and with ease. Please download the IP Search tool from PLANET Download Center.
  • Page 24: Chapter 3. Quick Setup

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Chapter 3. Quick Setup In this section users can learn how to query device IP and how to set language, account password, network and time zone through daemon. 3.1 Network Connection After the device is connected to the network, IP can be acquired automatically through DHCP server (The device IP will be preset to 192.168.0.10 if there is no DHCP server.).
  • Page 25 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Step 3: Host Setting The product is assigned dynamically (DHCP). To specify a fixed IP address, please fill in IP Address, Subnet Mask and Gateway. Press Next to continue. Step 4: DNS Setting Key in the DNS server, provided by ISP providers, and then you can set up two DNS servers.
  • Page 26 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Step 6: Time Format Select the time format to show in the system. Press Next to continue. Step 7: Time Server Setting User can set up device time synchronized with Time Server. Press Next to continue.
  • Page 27 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220...
  • Page 28: Chapter 4. Web-Based Management

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Chapter 4. Web-based Management This section provides instructions about how to use the web interface to configure and control the IP Power Manager remotely. 4.1 Monitor After a successful login, the web page will display the following operation menu where each part is...
  • Page 29 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Name Description of each power infeed. Each light signal has three states: "Normal", "Alert" and "No Access". Monitor Normal: “Offline Monitor” is checked. And external temperature is not higher than “High Alarm” or lower than “Low Alarm”...
  • Page 30: Outlet (For Ipm-4220)

    When the power outlet connects with a computer, in order to allow the computer to shut down normally before powering off, the computer must be installed and execute a safe shutdown program (Please go to PLANET website to download this program). After relevant parameters are set, safe shutdown program will be...
  • Page 31 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description registered on the computer and the computer state will show the sign giving normal registration. There are two computer states for power outlet: "Normal online state", and "Abnormal online state".
  • Page 32: Outlet (For Ipm-8220)

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Delete Group: Delete the group user that is not necessary. Group: Click on Add Group to create a group. After clicking it, Add Group window will pop up. Enter group name and mark the ports you expect to manage, and press Add to build the group, continuously adding is permitted here.
  • Page 33 (Please go to PLANET website to download this program). After relevant parameters are set, safe shutdown program will be registered on the computer and the computer state will show the sign giving normal registration.
  • Page 34 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Displays the current power outlet on-off state. For operation of power Switch outlet on/off, click the on/off icon with the mouse for commands of "On", “Off”, and “Reboot”. To be displayed after concatenation is enabled is the power outlet of...
  • Page 35: Temperature

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description 4.1.4 Temperature Display the information of Offline Monitor, Status and Temperature Value of the sensor. Parameters Description Name Description of temp port. Check to enable to monitor the state of temp sensor. When abnormal Offline Monitor temp occurs, device will send alert via the specified email.
  • Page 36 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description than “Low Alarm” setting. Non-Monitor Alert: “Offline Monitor” is not checked. And external temperature is higher than “High Alarm” or lower than “Low Alarm” setting. Non-Monitor Off-line: “Offline Monitor” is not checked.
  • Page 37: Rh Sensor

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Sensor state: Device Temp has 2 states: "Monitor Normal", and "Monitor Alert". Monitor Normal: “Offline Monitor” is checked. And external temperature is not higher than “High Alarm” or lower than “Low Alarm”...
  • Page 38: Daisy Chain

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Monitor Off-line: “Offline Monitor” is checked. Humidity Probe is not connected to PDU now. Non-Monitor Normal: “Offline Monitor” is not checked. And external humidity is not higher than “High Alarm” or lower than “Low Alarm”...
  • Page 39: Outlet Power Setup

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description The device of daisy chain. Model Outlet Total The outlet power port. Device of daisy chain has 2 states: "Monitor Normal", "Monitor Alert". Normal online state. Abnormal online state...
  • Page 40: Safe Shutdown

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Name Description of each power outlet. Set the number of seconds that device waits after a command is Power on delay issued before applying power to an outlet. Set the number of seconds that device waits after a command is Power off delay issued before removing power from an outlet.
  • Page 41: Schedule

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 4.2.3 Schedule In this option, work schedule of the time for power outlet on/off is seen. Parameters Description Set the work cycle of the power outlet; the cycle can be divided into Holiday, Month, Week, and Day.
  • Page 42: Monitor (Only For Ipm-8220)

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description The delay time for re-executing PING detection when the network Re-Ping time (Min.) device is on after network device reboots. 4.2.5 Monitor (Only for IPM-8220) This function provides the ability to set power outlet current value, real-time off of power outlet in case of any current abnormality to avoid any damage to the devices connected with the outlet.
  • Page 43: Copy

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Type: Use drop-down list to select peripheral type. (e.g., External Temp) Port: Select the port to be monitored. Term: You may choose the symbols: > (higher), < (lower) and = (equal).
  • Page 44: System

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Press "Save" after selecting a single power outlet or selecting all to copy the selected outlet parameters to the clicked power outlet(s). 4.3 System On this web page, users can set Network, Email server, Message server, SNMP, SysLog, Peripheral parameters, and other relevant data.
  • Page 45 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Configure the IP and DNS server addresses for Network Adapter Primary DNS Server Configure the IP and DNS server addresses for Network Adapter Secondary DNS Server Parameters Description Allows browser to connect with smart monitor by HTTP.
  • Page 46: Email Server

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Disable ICMP When Disable ICMP Response check box is selected, the examination will not be responded. Response 4.3.2 Email Server When there is a triggered warning from the setup of this PDU, this device will send out alert message to the preset email accounts.
  • Page 47: Sms Server

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Password The password to log in to mail server. After setting up the above info, you can send a test mail to make sure Email Test this function is normal.
  • Page 48: Ipm-4220 / Ipm

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description After setting up the above info, you can send a test mail to make sure SMS Test this function is normal. Parameters Description @@DEVICENAME@@ The device name will show when sending a message.
  • Page 49: Snmp

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 4.3.4 SNMP You can set up SNMP Agent and SNMP Trap on this page. Parameters Description SNMP v1/v2 Enable Enable SNMP v1/v2. SNMP Port Set the destination port. Default is 161.
  • Page 50: Syslog

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description For private password, use DES. Select DES type to key-in password. Private Password Parameters Description sysName The name displayed on SNMPAgent. sysContact The contact displayed on SNMPAgent. The location displayed on SNMPAgent.
  • Page 51: Serial Port (Uart)

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Host Enter Syslog Server Host IP. Port Enter Connect Port for Syslog Server. Default is 514. After setting up the above info, test it to make sure this function is Syslog Test normal.
  • Page 52: Peripheral Parameters

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description operate the device through terminal program API: Other devices can operate the current device through API protocol. As for the use of API, please refer to the appendix UART protocol.
  • Page 53 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description You may set up threshold current to avoid floating power triggered Released Load warning reaction. The warning will be dismissed by system when (Range) power current is lower than threshold current.
  • Page 54 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description High Temp Display the RCI type maximum load capacity for the temperature. Suggested High Display the RCI type high capacity for the temperature. Temp Suggested Low Display the RCI type low capacity for the temperature.
  • Page 55: Other

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description You may set up threshold current to avoid floating power triggered Direction (only for warning reaction. The warning will be dismissed by system when IPM-8220) power current is lower than threshold current.
  • Page 56: Firewall

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description MQTT Host Enter MQTT Host IP. MQTT Port Enter Connect Port for MQTT. Default is 1883. Parameters Description IP Lock-up Period The period of such IP has been locked up.
  • Page 57: Mac Filter

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Enable IP Filter Allow authorized IP address to access this device. After keying in permitted IP section, please click ADD to implement Allowed IP Section this action. To delete a specific IP address, please click “X”.
  • Page 58: Basic Info

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Modify Modify the previous setting. Operation of Alarm. Click Delete icon: browser will pop up a Confirmation of delete Delete window. Click Confirm: this Account cannot be utilized any longer.
  • Page 59: Outlet Authority

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 4.5.2 Outlet Authority Outlet Authority tab is mainly to open up outlet authority to other users. 4.5.3 Email System would send email when alarm occurs. Parameters Description Enable Alert Check to open email alarm system informed by email.
  • Page 60: Sms

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Use the checkbox to enable the setting. The system will follow the Parameter warning method you choose. Use the checkbox to enable the setting. When abnormal condition of Infeed infeed happens, system will send a warning message by the way you command.
  • Page 61 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Informed by short message, please fill out the right cellphone Cellphone number. Use the checkbox to enable the setting. The system will follow the Parameter warning method you choose.
  • Page 62: Time

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 4.6 Time You can set up the time server on this page. Parameters Description Device Time Date and time of the system. Time You may either scroll down to select Sync with computer or Manual Synchronization Setting.
  • Page 63: Chart

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description Enable daylight Set the Daylight saving time from Sunday to Saturday saving time 4.7 Chart This menu is mainly for query infeed, device temperature and statistic data. Parameters Description Category You may either scroll down to select infeed or device temperature.
  • Page 64: Event

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 4.8 Event The web page recorded the recent 200 logs, including the time, type and message. Parameters Description Refresh Click the Refresh button to refresh the screen. Click the Download button to save the event log information. The Download event log is saved in .txt format.
  • Page 65 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Parameters Description To update the firmware online, click “Browse…” to select the Upload firmware firmware. Then click “Upgrade” to proceed. Upload configuration Upgrade from previous saved setting. Download Download the current setting to PC.
  • Page 66: Chapter 5. Console Operation

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Chapter 5. Console Operation In this chapter, users can learn how to operate power On/off and set the network parameters through Console. When learning console operation, users should firstly set the type of device UART1 as Console and set relevant parameters.
  • Page 67 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 After setting is done, the HyperTerminal will display the sign-in menu; please enter the system account and password (admin and admin) established in device daemon. After entering finished, operation menu will be displayed to control power switch and set network data.
  • Page 68: Power Control

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 5.2 Power Control After selecting "OUTLET" from the main menu, press → or ^D to enter power control operation. Move Up and Down keys to move the cursor to the power outlet to be operated. When the Outlet is ON, press Tab for deciding the state of this line: Reboot or Off.
  • Page 69: System Preferences

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 5.3 System Preferences After selecting "SYS" from the main menu, press → or ^D to enter System Preferences setting. 5.3.1 Network Preferences After selecting "NetWork" from the main menu, press → or ^D to enter System Preferences setting.
  • Page 70: Firewall Preference

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 setting is modifying the system administrator password. 5.4 Firewall Preference After selecting "Firewall" from the main menu, press → or ^D to enter System Preferences setting.
  • Page 71: Reload Preference

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 5.5 RELOAD Preference After selecting "RELOAD" from the main menu, press → or ^D to enter the query windows to reload all data; if yes, press "Y", then the device will reload network, user and firewall data, and the data revised...
  • Page 72: Parameter Saving

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 5.6 Parameter Saving After selecting "SAVE" from the main menu, press → or ^D to enter the query windows to save and reboot the device; if yes, press "Y", then the device will save the revised data and reboot.
  • Page 73: Logout

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 5.7 Logout After selecting "LOGOUT" from the main menu, press → or ^D to enter the query windows; if press "Y" , then the terminal program will be logged out and the sign-in menu will be displayed.
  • Page 74: Appendix A: Resetting To Default Via Reset Button

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Appendix A: Resetting to Default via Reset Button Users who forget the network account and password of the product can press "Reset" to recover to the factory default values, and the device will reboot at the same time.
  • Page 75: Appendix B: Http Message Api Example

    IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Appendix B: HTTP Message API Example A Message API example of a message service provider is given below. The transmission mode is Get in TTP protocol, and the URL format is as follows: http://SMLWsip/httpSMLWs.php?Tag=Value&Tag=Value&Tag=Value…...
  • Page 76 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Press the icon on the right side of the screen to see message format as a reference. Parameters Description @@DEVICENAME@@ The device name will show when sending a message. @@ACCOUNT@@ The account will send the message.
  • Page 77 IP-based 4/8-port Switched Power Manager Power IPM-4220 / IPM-8220 Message format Description Company code (depid=xxxxxx) & Required User's Account Required (account=@@ACCOUNT@@)& User's password Required (password=@@PASSWORD@@)& Cellphone number Required (dstaddr=@@GSMLWNUM@@)& Device IP & Message content This format is changeable with the content.

This manual is also suitable for:

Ipm-8220

Table of Contents