Standard Specification; Converter Unit; Servo Amplifier - Mitsubishi Electric Melservo-H Series Specifications And Instruction Manual

General-purpose ac servo
Table of Contents

Advertisement

1. FUNCTIONS AND CONFIGURATION

1.4 Standard specification

1.4.1 Converter unit

Item
Voltage/frequency
Permissible voltage
Main circuit
fluctuation
power supply
Permissible frequency
fluctuation
Voltage/frequency
Permissible voltage
Control power
fluctuation
supply
Permissible frequency
fluctuation
Power consumption
Rated output
Regenerative power
(Using regenerative brake option)
Protective function
Structure
Ambient temperature
Ambient humidity
Storage temperture
Environment
Storage humidity
Ambient
Altitud
Vibration
Weight

1.4.2 Servo amplifier

Item
Voltage/frequency
Permissible voltage
Control power
fluctuaion
supply
Permissible frequency
fluctuation
Power consumption
Main circuit power supply
System
Structure
Ambient temperature
Humidity
Environment
Ambience
Altitude
Vibration
Weight
Function
Model
3-phase 200 to 230VAC, 50/60Hz
3-phase 170 to 253VAC, 50/60Hz
Within 5%
1-phase 200 to 230VAC, 50/60Hz
1-phase 170to 235VAC, 50/60Hz
Within 5%
50W
30kw
One MR-RB139: 1300W
Three MR-RB139s: 3900W
Regenerative overvoltage shutoff, overload shutoff (electronic thermal protector)
Regenerative alarm protection, undervoltage, instantaneous power failure protection
Open(IP00)
0 to
55 [°C] (non-freezing)
32 to
131 [°F] (non-freezing)
90%RH or less (non-condensing)
20 to 65 [°C] (non-freezing)
4 to 149 [°F] (non-freezing)
90%RH or less (non-condensing)
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Max. 1000m (3280 ft) above sea level
5.9 [m/s
] or less
2
19.4 [ft/s
] or less
2
[Kg] [lb]
22 [48.502]
Servo amplifier
Single-phase 200 to 230VAC, 50/60Hz
Single-phase 170 to 253VAC, 50/60Hz
Within 5%
50W
The main circuit power of the servo amplifier is supplied by the converter unit.
Sine-wave PWM control, current control system
Open (IP00)
0 to
55 [°C] (non-freezing), storage:
90%RH or less (non-condensing), storage: 90%RH or less (non-condensing)
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Max. 1000m (3280ft) above sea level
5.9 [m/s
] or less
2
Kg [lb] 47 [103.617]
Refer to the corresponding Servo Amplifier Instruction Manual of 22kW or less.
MP-HP30K
MR-H30K
20 to 65 [°C] (non-freezing)
1 - 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-h30kbnMr-h30kanMr-h30kacnMr-h30kdnMr-h30ktn

Table of Contents