No. Item
11
Power Supply
(PSU2)
More information can be found in the Back-panel features and indicators section of the Dell Owner's
Manual.
Related links
Physically connecting the new server
Dell R630 server altitude and air pressure requirements
Operating altitude de-rating
Storage
Related links
Physically connecting the new server
Dell R630 server physical specifications
Type
Dimensions
Weight (maximum
configuration)
Related links
Physically connecting the new server
Dell R630 server temperature and humidity requirements
Specification
Temperature range
August 2017
Icon
Description
Wattage and voltage type depends on configuration.
on page 26
Altitude
Maximum altitude 3,048m (10,000ft)
Note:
• Up to 35°C (95°F): Maximum temperature is reduced by
• 35°C to 40°C (95°F to 104°F): Maximum temperature is
• 40°C to 45°C (104°F to 113°F): Maximum temperature is
Maximum altitude 12,000m (39,370 ft)
on page 26
Description
Height: 4.28 cm (1.69 inch)
Width: 48.24 cm (18.99 in)
Depth: 70 cm (27.58 in)
18.6 kg (41 lb)
on page 26
Value
Installing the Avaya Equinox Streaming and Recording Server
Comments on this document? infodev@avaya.com
1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).