Process controller (PCTRL1)

Purpose
The FB is used, for instance, as a higher−level controller (dancer position controller, tension controller,
pressure controller etc.).
The control characteristic follows the ideal PID algorithm, but it can also be changed over to a PI or
P characteristic.
Fig. 3−184
Process controller (PCTRL1)
Name
PCTRL1−SET
PCTRL1−ACT
PCTRL1−INFLU
PCTRL1−ADAPT
PCTRL1−INACT
PCTRL1−I−OFF
PCTRL1−OUT
Function
Setpoint and actual value are sent to the process controller via the corresponding inputs and
processed according to the selected control algorithm (control chararacteristic).
l
PCTRL1-ADAPT
C0803
C0808/4
2
3
C0332
PCTRL1-SET
C0800
C0808/1
C0333
PCTRL1-ACT
C0801
C0808/2
PCTRL1-INACT
C0804
C0809/1
PCTRL1-I-OFF
C0805
C0809/2
PCTRL1-INFLU
C0802
C0808/3
Signal
Type
DIS
DIS format
a
C0808/1
dec [%]
a
C0808/2
dec [%]
a
C0808/3
dec [%]
a
C0808/4
dec [%]
d
C0809/1
bin
d
C0809/2
bin
a
EDSVS9332P−EXT DE 2.0
Function library
Function blocks
Process controller (PCTRL1)
C0222
Vp
C0222
Vp2
C0325
C0222
Vp
C0325
Vp2
Vp3
C0326
soll1
soll2
C0327
C0328
C0337
C0223
C0224
±100%
+
-
RESET
Source
CFG
List
Lenze
C0800
1
1000
C0801
1
1000
C0802
1
1000
C0803
1
1000
C0804
2
1000
C0805
2
1000
PCTRL1
C0329
0
1
2
3
C0336
PCTRL1-OUT
Note
Input of the process setpoint. Possible
value range: ±200%. The time
characteristic of step−change signals can
be affected via the ramp function generator
(C0332 for the acceleration time; C0333 for
the deceleration time).
Actual value input; value range ±200%
Evaluation or suppression of the output
signal; value range ±200%
Online change of the P gain;
value range ±200%
Online deactivation of the process
controller
Online setting of the I component to zero
3−237