Function library
Function blocks
3.5.33
Freely assignable digital outputs (DIGOUT)
3.5.33
Freely assignable digital outputs (DIGOUT)
Purpose
Conditioning of the digital signals and output at the terminals X5/A1 to X5/A4.
Fig. 3−136
Freely assignable digital outputs (DIGOUT)
Name
DIGOUT1
DIGOUT2
DIGOUT3
DIGOUT4
Function
The terminals X5/A1 to X5/A4 are updated every millisecond. The level for every output can be
inverted. For this, proceed as follows:
l
Select code C0118 with corresponding subcode (e.g. subcode 3 for output X5/A3)
l
Enter the desired level as a parameter:
– 0 = Level not inverted (HIGH active)
– 1 = Level inverted (LOW active)
3−186
C0117/1
C0117/2
C0117/3
C0117/4
Signal
Type
DIS
DIS format
d
C0444/1
bin
d
C0444/2
bin
d
C0444/3
bin
d
C0444/4
bin
EDSVS9332P−EXT DE 2.0
DIGOUT
DIGOUT1
X5
C0118/1...4
DIGOUT2
A1
DIGOUT3
0
DIGOUT4
A2
1
1
C0444/1
A3
C0444/2
C0444/3
A4
C0444/4
Source
CFG
List
Lenze
C0117/1
2
15000
C0117/2
2
10650
C0117/3
2
500
C0117/4
2
5003
Note
−
−
−
−
l