13.1 Floor Space And Maintena nce Area
Sufficient floor space and maintenance area must be available when installing A
Floor Space
The floor space must have a sufficient load carrying capacity and be sufficiently flat (according to
DIN 18202). It must not sag by more than 1 millimeter under the load of the A
ment, wood or false floor is permissible.
The load of the A
TLAS
No installations (venting ducts, sockets etc.) must be present in the floor in the area of the feet or
of the lower anchoring devices. An area of at least 15 centimeters must be kept free around each
foot. The loading capacity in the area of the feet must be sufficient. Height differences up to
±5 millimeters can be compensated using the adjustable feet.
A
67 CS4
TLAS
R5976255 A
CS4 (2001-03)
TLAS
CS4 is transmitted to the floor via adjustable feet.
front
1335
752,5
154.5
top
CS4
TLAS
TLAS
side
Position of the feet of A
(All dimensions measured in millimeters!)
CS4. A ce-
Figure 13-1
67 CS4