Replacement
1.
To install, do the removal steps in reverse order.
2.
Insert the Connector Housing of the Toner Empty Sensor into the square hole of the frame
(Figure 3).
A Square hole
Initial Issue
WorkCentre 5020
Figure 3
REP 4.2.2 Erase Lamp
Parts List on PL 4.2
Removal
To avoid personal injury or electrical shock, ensure that the machine is completely off
before disassembling or adjusting. Turn OFF the power and unplug the machine.
1.
Remove the Drum Cartridge (REP 4.1.1).
2.
Remove the Output Tray (REP 9.1.1).
3.
Remove the Rear Cover (REP 9.2.1).
4.
Remove the Transfer Corotron Housing (REP 4.3.1).
5.
Remove the HVPS and Contact Block (REP 8.2.1).
July, 2007
4-21
WARNING
Repairs and Adjustments