Rep 10.2.1 Iit Upper Cover (Scc) - Xerox WorkCentre 5020 Service Documentation

Hide thumbs Also See for WorkCentre 5020:
Table of Contents

Advertisement

REP 10.2.1 IIT Upper Cover (SCC)

Parts List on PL 10.2
Removal
To avoid personal injury or electrical shock, ensure that the machine is completely off
before disassembling or adjusting. Turn OFF the power and unplug the machine.
1.
Remove the following parts:
Platen Cover (PL 10.1)
Control Panel (REP 8.3.1)
2.
Remove the screws that secure the IIT Upper Cover (Figure 1).
1 Remove the screws (7).
2 Remove the Tapping Screws (2).
3 Remove the cap.
Repairs and Adjustments
REP 10.2.1
WARNING
Figure 1
3.
Remove the IIT Upper Cover (Figure 2).
1 Press the tabs (2) to release them.
NOTE: The tabs are visible through the Platen Glass.
2 Open the right side of the IIT Upper Cover.
3 Press the tabs (2) to release them, and remove the IIT Upper Cover.
Replacement
1.
To install, do the removal steps in reverse order.
July, 2007
4-66
Figure 2
Initial Issue
WorkCentre 5020