REP 7.1.1 Simplex Module
Parts List on PL 7.1
Removal
To avoid personal injury or electrical shock, ensure that the machine is completely off
before disassembling or adjusting. Turn OFF the power and unplug the machine.
1.
Remove the Rear Cover (REP 9.2.1).
2.
Tape the Bypass Tray so that it cannot open by itself (Figure 1).
1 Apply 2 pieces of tape as shown.
Initial Issue
WorkCentre 5020
WARNING
Figure 1
3.
Open the Left Side Cover.
4.
Disconnect the connector (Figure 2).
1 Disconnect P/J 502.
2 Remove the wire harness from the hook.
3 Remove the wire harness from the groove in the frame.
4 Remove the wire harness from the guides (5).
5 Remove the wire harness from the groove in the frame.
6 Remove the wire harness from the hooks (3).
July, 2007
4-43
Figure 2
Repairs and Adjustments
REP 7.1.1