Commissioning and configuration
Attention!
Activation of the config assembly as described above necessitates value entry in the corre-
sponding parameter memory locations. When using the configuration assembly, the default
parameters must also be entered in the corresponding memory locations (see also "Setting
MA parameters manually via the config assembly" on page 74).
After all of the parameters relevant to the MA
"online" and the project is downloaded again.
Setting MA parameters manually via the config assembly
Notice!
If the device was integrated into an older-version control without EDS support using the
generic module, the following option exists to change parameters of the MA:
After setting up the device with the generic module, the MA appears in the RSlogix software
in the file structure on the left among the
 Display the reserved control area (MA200.C in this case) by double-clicking on the MA
entry.
 Now enter the parameters manually into bytes 00-11.
Subsequent adaptations may be made by changing the respective position.
Please find a detailed description of the Leuze-specific assembly in chapter 12.6.2.
Byte 00+01:
Byte 02+03:
Byte 04+05:
Byte 06+07:
Byte 08+09:
Byte 10+11:
74
Controller tags
DataMode (collective/transparent mode)
Serial line mode (rotary / EDS)
Baud rate (9600Bd)
Data bits (7/8 data bits)
Parity (N/E/O)
Stop bits (1/2)
MA
258i
258i
are entered, the control is switched to
.
Leuze electronic