Electrical connection
7.2.2

PWR OUT switching input/output

PWR OUT
SWIO_2
VOUT 1
SWIO_1
M12 socket
(A-coded)
Table 7.2:
Notice!
The maximum admissible current of the PWR OUT and IN connectors is maximum 3A. To
be subtracted from this is the current consumption of both the MA and of the connected
end device.
The function of the switching inputs and outputs is dependent on the connected Leuze
device. Detailed information on this topic can be found in the respective operating instruc-
tions.
On delivery, the SWIO 1/2 are connected in parallel on PWR IN/OUT. This connection can
be separated with a jumper.
7.3

BUS IN

The MA
258i
TD+ 1
M12 socket
Table 7.3:
38
PWR OUT (5-pin socket, A-coded)
Pin
2
GND
3
5
4
FE
Thread
PWR OUT pin assignment
provides an EtherNet/IP interface as a HOST interface.
BUS IN
RD+
2
TD-
3
4
RD-
(D-coded)
EtherNet/IP BUS IN pin assignment
Name
1
VOUT
2
SWIO_2
3
GND
4
SWIO_1
5
FE
FE
BUS IN (4-pin socket, D-coded)
Pin
Name
1
TD+
2
RD+
3
TD-
4
RD-
Thread
FE
MA
258i
Remark
Voltage supply for additional devices
(VOUT identical to VIN at PWR IN)
Switching input/switching output 2
GND
Switching input/switching output 1
Functional earth
Functional earth (housing)
Remark
Transmit Data +
Receive Data +
Transmit Data -
Receive Data -
Functional earth (housing)