Modular Interfacing Unit Ma 3X (S4 Switch Position C) - Leuze electronic MA 258i Operating Instructions Manual

Fieldbus gateway - ethernet/ip
Table of Contents

Advertisement

Specifications for Leuze end devices

16.12 Modular interfacing unit MA 3x (S4 switch position C)

Specifications for the serial interface
Default parameter
Baud rate
Data mode
Handshake
Protocol
Frame
Specifications for Command mode
To activate the Command mode, bit 0 must be set to 1 in control byte 0.
For further information, see chapter 11.1.3 "Command mode", figure 11.2.
Control bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Recommended settings
• Produced data/Consumed data:
dependent on the number of digits of the code that is to be read.
With an 18-digit bar code (+ 2 bytes of status bytes + 2 bytes of slave address), for
example, it is advisable to use the "64 bytes In/4 bytes Out" combination.
Notice!
In this switch position, the address of the multiNet slave is also transmitted in the first two
bytes of the data range!
110
MA 3x
9600
8N1
no
framing protocol without acknowledgment
<STX> <Data> <CR> <LF>
Meaning
Version query
Reset parameters to default values
Device restart
MA
258i
Corresponds to
serial command
(ASCII)
v
PC20
H
Leuze electronic