Electrical connection
7.4

BUS OUT

BUS OUT
TD+ 1
M12 socket
Table 7.4:
 For the host connection of the MA 258i, the "KB ET - ... - SSA" ready-made cables are
preferred, see table 14.4 Bus connection cable for the MA 258i on page 94.
Notice!
Ensure adequate shielding. For the devices and ready-made cables offered by
Leuze electronic, the shield is on PIN 1.
If you use user-configurable cables, note the following:
Notice!
Ensure adequate shielding. The entire connection cable must be shielded and earthed. The
signal lines must be stranded in pairs.
Use CAT 5 cable for the connection.
Notice!
For the MA
nation on the BUS OUT socket is not mandatory!
40
BUS OUT (4-pin socket, D-coded)
RD+
2
TD-
3
4
RD-
(D-coded)
EtherNet/IP BUS OUT pin assignment
258i
as standalone device or as the last participant in a linear topology, termi-
Pin
Name
1
TD+
2
RD+
3
TD-
4
RD-
Thread
FE
MA
258i
Remark
Transmit Data +
Receive Data +
Transmit Data -
Receive Data -
Functional earth (housing)