Pwr Out Switching Input/Output; Bus In - Leuze electronic MA 204i Technical Description

Modular interfacing unit for leuze ident and rs 232 devices on profibus dp
Table of Contents

Advertisement

Electrical connection
7.2.2

PWR OUT switching input/output

PWR OUT
SWIO_2
VOUT 1
SWIO_1
M 12 socket
(A-coded)
Table 7.2:
Notice!
The maximum admissible current of the PWR OUT and IN connectors is maximum 3 A. To
be subtracted from this is the current consumption of both the MA and of the connected
end device.
The function of the switching inputs and outputs is dependent on the connected Leuze
device. Detailed information on this topic can be found in the respective operating
instructions.
On delivery, the SWIO 1/2 are connected in parallel on PWR IN/OUT. This connection can
be separated with a jumper.
7.3

BUS IN

The MA
204i
HOST / BUS IN
GND 485 3
FE
M 12 connector
Table 7.3:
 For the host connection of the MA 204i, the ready-made KB PB-xxxxx-Bx cables are
preferred, "Bus connection cable for the MA 204i" on page 78.
30
PWR OUT (5-pin socket, A-coded)
Pin
2
GND
3
5
4
FE
Thread
Pin assignment PWR OUT
provides a PROFIBUS DP interface as a HOST interface.
A (N)
2
N.C.
1
5
4
B (P)
(B-coded)
Pin assignments for PROFIBUS DP BUS IN
Name
1
VOUT
2
SWIO_2
3
GND
4
SWIO_1
5
FE
FE
BUS IN (5-pin plug, B-coded)
Pin
Name
1
N.C.
2
A (N)
3
GND 485
4
B (P)
5
FE
Thread
FE
MA
204i
Remark
Voltage supply for additional devices
(VOUT identical to VIN at PWR IN)
Switching input/switching output 2
GND
Switching input/switching output 1
Functional earth
Functional earth (housing)
Remark
Not used
Receive/transmit data A-line (N)
RS 485 ground reference for bus
termination
Receive/transmit data B-line (P)
Functional earth / shield
Functional earth (housing)
Leuze electronic